background image

Z-Wave Configuration Command

Parameter value range

Parameter Number

Definitions

o

o

0x01 = 0.5  C / 1  F

o

 

o

0x02 = 1.0  C / 2 F 

(default)

o

o

0x03 = 1.5  C / 3  F

 

o

o

0x04 = 2.0 C / 4  F

1 (0x01)

Swing

o

o

0x01 = 0.5  C / 1  F

o

 

o

0x02 = 1.0  C / 2 F 

(default)

o

o

0x03 = 1.5  C / 3  F

 

o

o

0x04 = 2.0 C / 4  F

2 (0x02)

Differential

0x01F4 to 0x0FA0 

(default = 0x01F4, 

resolution = 0x0064)

(500 to 4000 hours; 
resolution=100hrs )

3 (0x03)

Set filter counter

0x0000 to 0x270F
(0 to 9999 hours)

4 (0x04)

Report filter counter

(read only)

(A) available range:

o

Celsius ( C):

o

A = (B+2)min. ~ (37.0 C) max. 

o

Fahrenheit ( F):

o

A = (B+4)min. ~ (99.0 F) max.

o

       

(default = 99.0 F)

6 (0x06)

Upper limit of set point (A)

o

0x00 =  C

o

0x01 =  F 

(default)

5 (0x05)

Scale of temperature

(B) available range:

o

o

o

Celsius ( C): 5.0 C to 35.0 C

o

o

o

Fahrenheit ( F): 41.0 F to 95.0 F

o

                         

(default = 41.0 F)

7 (0x07)

Lower limit of set point (B)

0x00 = Disable (Normal mode)
0x01 = Enable (Simple mode), 
            

default

8 (0x08)

Simple mode

0x00 = 24 hours
0x01 = 12 hours (am / pm), 

default

9 (0x09)

Time format

22

Value(X): 0x00, 0x03 to 0xFF
0X00 = Disable, 

default

Range from 0x03 to 0xFF =
3 minutes to 255 minutes
(Thermostat sends "Basic Set"
command to its association node
repeatedly in every X minutes)

10 (0x0A)

Repeat basic set counter

Содержание Z-Thermostat ZTS-100

Страница 1: ...ZTS 100 Z Thermostat USER MANUAL...

Страница 2: ...Product Overview Description of Function Keys Change Operation Mode Select Fan Mode Select Program Mode Override Permanent Override Temperature Scale selection for SIMPLE mode 15 Add ZTS 100 to Gatewa...

Страница 3: ...rough the Z Wave gateway control ZTS 100 can be configured as either Frequently Listening Routing Slaves FLiRS or Always Listening node and it will distinguish the power source batteries or 24Vac auto...

Страница 4: ...ogram settings Temperature Display and Control o o Temperature display in F or C o o Temperature Measurable Range 32 99F 0 40 C o o Temperature Setting Range 41 99F 5 37 C Adjustable Temperature Contr...

Страница 5: ...mplement Adaptive Source Routing A collection of Z Wave devices is controlled by primary and secondary controllers operating on the same system A Z Wave network has its own unique ID code so that cont...

Страница 6: ...s Inclusion Controller CAUTION Read the enclosed instructions carefully before installing your new Z Thermostat Pay close attention to all warnings and notes and carefully follow the installation step...

Страница 7: ...f cable provided with a metal sheath Recommends adding fuse or protective device in the line circuit Important The ZTS 100 can be powered by alkaline batteries AA x 4pcs or 24Vac Connect the 24Vac Com...

Страница 8: ...ems Figure 2 Non heat pump Standard Gas or Electric HVAC system wiring Figure 3 Heat pump system wiring 7 Standard HVACSystem nd W2 2 stage heater st W1 1 stage heater G Fan Y Compressor R 24VacPower...

Страница 9: ...hole near the terminal block 6 Insert 2 pieces of wall anchors into the holes of the wall 7 Fasten the thermostat with 2 pieces of long screws through the 2 mounting holes Figure 6 8 Install the top h...

Страница 10: ...Wave thermostat controllers are designed and manufactured by various vendors whom are compatible with your ZTS 100 as long as they carry the Z Wave logo Please carefully read through the following th...

Страница 11: ...lect fan mode also the Backward function key in some menus Change operation mode also the Forward function key in some menus Select program mode PROG ON OVERRIDE and PERMANENT OVERRIDE also the Confir...

Страница 12: ...2 WAKE AM MO FAN ON COOL LCD indication Step Procedure Description Press Prog key once to select PROG mode PROG ON OVERRIDE PERMANENT OVERRIDE PROG ON Run the schedule 1 WAKE AM MO FAN AUTO COOL PROG...

Страница 13: ...or COOL mode Press Prog key once to confirm the setting 2 TARGET HEAT OVERRIDE AM MO FAN AUTO TARGET OVERRIDE COOL or In AUTO mode user needs to set heat and cool set points temperature Press Up Down...

Страница 14: ...ey for 2 seconds to entry the setting mode It will display EASY YES if it stays in SIMPLE mode Otherwise it will display EASY no if it stays in NORMAL mode Press Up Down key to toggle the selection Pr...

Страница 15: ...press Up Down key to set minutes 4 Press Prog key once to confirm the setting and it will go to 12 24 hour clock selection Press Up Down key to toggle the 12 24 hour clock selection 5 AM PM HR Press P...

Страница 16: ...nfirm the setting and it will go to Advanced Recovery setting Press Up Down key to enable disable Advanced Recovery Mode 9 RECOVERY RECOVERY Press Prog key once to confirm the setting and it will go t...

Страница 17: ...hedule 1 Time Event MO I FR Heat Cool WAKE AWAY HOME SLEEP 6 00AM 8 00AM 6 00PM 10 00PM o o 70 F 21 C o o 62 F 17 C o o 70 F 21 C o o 62 F 17 C o o 78 F 26 C o o 85 F 29 C o o 78 F 26 C o o 82 F 28 C...

Страница 18: ...hour setting Hour will keep flashing press Up Down key to set hour 3 WAKE AM MO TU WE TH FR Press Prog key once to confirm the setting and it will go to minutes setting Minutes will keep flashing pres...

Страница 19: ...xt event setting 6 WAKE TARGET AM MO TU WE TH FR HEAT Press Prog key once to confirm the setting and it will go to target setting Target will keep flashing press Up Down key to adjust Cool set point f...

Страница 20: ...al to ensure that the signal is received by its intended destination by routing the signal around obstacle and radio dead spots Application for out of 24Vac power line 1 Install AAx4pcs batteries and...

Страница 21: ...ndication Step Procedure Description Gateway Controller device should entry the inclusion mode Press and hold Home key for 2 seconds to entry the Add Inclusion Delete Exclusion Mode 1 Press Prog key o...

Страница 22: ...heating mode Association group_2 ZTS 100 will send out basic set command 0xFF automatically once Compressor operation has been started in cooling mode ZTS 100 will send out basic set command 0x00 aut...

Страница 23: ...ange o Celsius C o A B 2 min 37 0 C max o Fahrenheit F o A B 4 min 99 0 F max o default 99 0 F 6 0x06 Upper limit of set point A o 0x00 C o 0x01 F default 5 0x05 Scale of temperature B available range...

Страница 24: ...ter page Press Home key once to go back to the Home page 3 TARGET FILTER HR FILTER icon will be shown on the screen at Home page when the usage hours were reached to set time 4 WAKE FILTER AM PROG ON...

Страница 25: ...reset to factory default settings The following data will be reset to default 1 Clock 12 00am 2 Day Mon 3 Temperature scale F 4 Swing 2F 5 Diff 2F 6 Default schedule 7 Operation mode OFF 8 Default He...

Страница 26: ...C All heaters will be forced Off Cooler will turn on if running cool mode 1 WAKE AM TU FAN AUTO 1 COOL LO icon will be displayed on LCD if temperature below the measurement o o ranges 32 F 0 C All he...

Страница 27: ...alculates the time needed to adjust the temperature to the next program setting When the thermostat is in Advanced Recovery mode the display will show RECOVERY Advanced Recovery is an option that allo...

Страница 28: ...is the max units if yes A Yes and it is very depends on the capability of gateway controller For example gateway can supports up to 8 16 or 32 ZTS 100 in a network Q Where can I keep up to date with t...

Страница 29: ...set point Example 1 If user select heat set point is 70F the minimum cool set point will be o o limited at heat set point 4 F 74 F o o Pervious heat set point is 70 F and cool set point is 74 F o Exam...

Страница 30: ...ation groups LCD TN type with white backlight VA 66 5mmx28 5mm Powered by Dry battery AA x 4pcs or 24 VAC 20 50 60Hz Relay contact Voltage 24 VAC 50 60 Hz Current 1A Max inductive Temperature measurab...

Страница 31: ...interference that may cause undesired operation Z Wave Command Class Controlled Supported COMMAND_CLASS_THERMOSTAT_FAN_MODE NO YES COMMAND_CLASS_THERMOSTAT_FAN_STATE NO YES COMMAND_CLASS_THERMOSTAT_MO...

Страница 32: ...RNS Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available Caut...