Z-Wave Configuration Command
Parameter value range
Parameter Number
Definitions
o
o
0x01 = 0.5 C / 1 F
o
o
0x02 = 1.0 C / 2 F
(default)
o
o
0x03 = 1.5 C / 3 F
o
o
0x04 = 2.0 C / 4 F
1 (0x01)
Swing
o
o
0x01 = 0.5 C / 1 F
o
o
0x02 = 1.0 C / 2 F
(default)
o
o
0x03 = 1.5 C / 3 F
o
o
0x04 = 2.0 C / 4 F
2 (0x02)
Differential
0x01F4 to 0x0FA0
(default = 0x01F4,
resolution = 0x0064)
(500 to 4000 hours;
resolution=100hrs )
3 (0x03)
Set filter counter
0x0000 to 0x270F
(0 to 9999 hours)
4 (0x04)
Report filter counter
(read only)
(A) available range:
o
Celsius ( C):
o
A = (B+2)min. ~ (37.0 C) max.
o
Fahrenheit ( F):
o
A = (B+4)min. ~ (99.0 F) max.
o
(default = 99.0 F)
6 (0x06)
Upper limit of set point (A)
o
0x00 = C
o
0x01 = F
(default)
5 (0x05)
Scale of temperature
(B) available range:
o
o
o
Celsius ( C): 5.0 C to 35.0 C
o
o
o
Fahrenheit ( F): 41.0 F to 95.0 F
o
(default = 41.0 F)
7 (0x07)
Lower limit of set point (B)
0x00 = Disable (Normal mode)
0x01 = Enable (Simple mode),
default
8 (0x08)
Simple mode
0x00 = 24 hours
0x01 = 12 hours (am / pm),
default
9 (0x09)
Time format
22
Value(X): 0x00, 0x03 to 0xFF
0X00 = Disable,
default
Range from 0x03 to 0xFF =
3 minutes to 255 minutes
(Thermostat sends "Basic Set"
command to its association node
repeatedly in every X minutes)
10 (0x0A)
Repeat basic set counter
Содержание Z-Thermostat ZTS-100