Average condition WSP 140/180
1)
Series
WSP 140
WSP 180
Energy efficiency ratio, heating 35 °C/55 °C
A+++/A+++
A+++/A++
Energy efficiency ratio, hot water XL
A
A
Nominal heating power P rated 35 °C/55 °C
kW
11,0/9,0
17,0/15,0
Room heating energy efficiency
h
s 35 °C/55 °C
%
201/178
224/138
Contribution to seasonal room heating energy efficiency of the
REMKO Smart Control
%
4
4
Yearly energy consumption Q
HE
35 °C/ 55 °C
4)
kWh
4308/4087
6136/8476
Sound power level L
WA
(heat pump)
dB(A)
45
45
Warmer condition WSP 140/180
2)
Series
WSP 140
WSP 180
Energy efficiency ratio, heating 35 °C/55 °C
A+++/A+++
A+++/A++
Energy efficiency ratio, hot water XL
A
A
Nominal heating power P rated 35 °C/55 °C
kW
11.0/9.0
17.0/15.0
Room heating energy efficiency
h
s 35 °C/55 °C
%
199/176
226/139
Yearly energy consumption Q
HE
35 °C/ 55 °C
4)
2807/2667
3921/5447
Colder condition WSP 140/180
3)
Series
WSP 140
WSP 180
Energy efficiency ratio, heating 35 °C/55 °C
A+++/A+++
A++/A+++
Energy efficiency ratio, hot water XL
A
A
Nominal heating power P rated 35 °C/55 °C
kW
16.0/15.0
26.0/23.0
Room heating energy efficiency
h
s 35 °C/55 °C
%
191/172
223/144
Yearly energy consumption Q
HE
35 °C/ 55 °C
4)
8135/7985
11009/15195
1)
Average condition = Moderate temperature periods
2)
Warmer condition = Warm temperature periods
3)
Colder condition = Cold temperature periods
4)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit.
13