WKL 20 INOX

 

Rated heat power Q

B

 

kW 

18 

Rated heat output Q

N

 

kW 

16,7 

Rated air output V

N

  (at 

 

t

 45 K / 1,2 kg/m³) 

m³/h 

1050 

Fuel 

Oil throughput  m

B

 max. 

kg/h 

1,52 

Exhaust mass current  V

Af   

 

kg/h 

28,5 

Exhaust temperature approx. t

A

  

°C 

170 – 180 

Required chimney draught 

Pa 

Exhaust loss  q

A

  min./ max. 

7 / 11 

Required chimney draught approx. (start / operation) 

Pa 

60 / 8 

Electrical connection 

230 / 1~ 

Frequency 

Hz 

50 

Rated current max.  (unit without burner) 

1,1 

Power consumption max.  (unit without burner) 

kW 

0,17 

Power consumption max.  (for manufacturer-supplied burner) 

kW 

0,28 

Sound pressure level L

pA 1m  

(without burner) 

dB(A) 

58 

Waste gas connection Ø 

mm 

130 

Weight (Unit without burner) 

kg 

90 

Dimensions :  Width, total 

mm 

490 

 

Height, total, (without blow-out hood) 

mm 

1465 (1090) 

 

Length, total (without burner, with waste gas connection) 

mm 

620 (720) 

Heating oil EL 

 

Oil nozzle (Danfoss/Steinen) 

USG 

0,45 / 60°S 

Pump pressure, approx.  

bar 

10 

Pessure p

N

 max. complete 

Pa 

62 

Technical Data

 

Max. suction temperature 40 °C / max. outgoing temperature 100 °C

 

We reserve the right to make modifications in dimensions and construction in the interests of technical progress. 

Содержание WKL 20 INOX

Страница 1: ...REMKO powerful like a bear REMKO WKL 20 INOX Oil compact heating system Edition GB P11 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...Oil Burner Assembly 16 Initial Operation 16 Service and Guarantee 17 Maintenance Log 18 Stationary Warm Air Heating System REMKO WKL 20 INOX Read these instructions carefully before setting up operati...

Страница 4: ...connect the units to an exhaust system approved by the state building authorities The units are equipped with a 1 speed radial fan with drive motor that runs quietly and requires little mainte nance a...

Страница 5: ...bend the capillary tubes near to solder points When installing the capillary tubes be careful not to damage or bend them too sharply The sensors may only be mounted in the mounting brackets supplied b...

Страница 6: ...tup room but not close to hazardous areas Air Supply for Combustion An adequate supply of air for combustion must be en sured by meeting the relevant building requirements Excerpts from the German fir...

Страница 7: ...e units the regional provisions and regulations must be observed The units may only be operated with accessories that have either been approved by the manufacturer or sup plied with the units Proceed...

Страница 8: ...f the burner sup plied by the manufacturer If burners from other manufacturers are used they must be checked for compatibility with the unit Fan Motor Connection The units are completely wired at the...

Страница 9: ...If the unit is not set to its rated heat load or it is too large for the necessary heat requirements the burner only runs in cyclical operation Because the required operating temperature is not reache...

Страница 10: ...er Combustion residue in the com bustion chamber and in the heat exchanger must be removed Parts that wear out e g flue gas brakes oil nozzles oil filter inserts seals etc must be checked cleaned and...

Страница 11: ...and capillary pipes of the safety temperature limiter STB and the temperature moni tor TW for damage and ensure that the sensor has been properly positioned Check whether the red control light burner...

Страница 12: ...max unit without burner kW 0 17 Power consumption max for manufacturer supplied burner kW 0 28 Sound pressure level LpA 1m without burner dB A 58 Waste gas connection mm 130 Weight Unit without burne...

Страница 13: ...ture limiter TH Optional Room thermostat or day night regulator TR Fan control thermostat TW Temperature monitor WS Wieland plug We reserve the right to make modifications in dimensions and constructi...

Страница 14: ...Exploded View 4 1 2 5 3 13 8 9 12 11 7 3 4 10 16 15 20 18 19 17 21 22 23 26 25 27 14 24 6 We reserve the right to make modifications in dimensions and construction in the interests of technical progre...

Страница 15: ...ction grille 289109 16 Fan cpl 1108606 17 Seal for inspection cover 1103156 18 Inspection cover with waste gas connection 1103155 19 Waste gas suppressor set 6 piece 1103157 20 Fan control thermostat...

Страница 16: ...manually but not so that they are completely tight initially The sliding flange still has to be tightened 4 Push the flame pipe into the burner chamber until it clicks into place 5 Connect the flame p...

Страница 17: ...the guarantee to be valid the customer must com pletely fill out the guarantee certificate enclosed with all heating units and send it back to REMKO GmbH Co KG in a timely manner after purchasing of t...

Страница 18: ...damage Maintenance burner Test run Model Model No Burner Burner No Maintenance work may only be performed by authorised personnel settings must comply with legal specifications A corresponding test lo...

Страница 19: ......

Страница 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606 260 E Mail info remko de Internet www remko de...

Отзывы: