SECTION A SAFETY
-
These warnings apply to RT series basic pumps. Remko has no control over or
particular knowledge of the power source which will be used. Refer to the manual
accompanying the power source before attempting to begin operation.
4
This pump is designed to handle mild industrial corrosives, mud or
slurries containing large entrained solids. Do not attempt to pump
volatile, corrosive, or flammable materials which may damage the
pump or endanger personnel as result of pump failure.
WARNING!
After the pump has been positioned, make certain that the pump and
all piping connections are tight, properly supported and secure
before operation.
Do not operate the pump without the guards in place over the
rotating parts.
Exposed rotating parts can catch clothing, fingers, or tools, causing
severe injury to personnel.
Use lifting and moving equipment in good repair and with
adequate capacity to prevent injuries to personnel or damage to
equipment. Suction and discharge hoses and piping must be
removed before lifting.
Do not remove plates, covers, gauges, pipe plugs, or fittings from an
overheated pump. Vapour pressure within the pump can cause parts
being disengaged to be ejected with great force. Allow the pump to
cool before servicing.
Do not operate the pump against a closed discharge valve for long
periods of time. If operated against a closed discharge valve,
pump components will deteriorate, and the liquid could come to a
boil, pressure, and cause the pump casing to rupture or explode .
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
Before attempting to open or service the pump
:
1. Familiarize yourself with this manual.
2. Disconnect or lock out the power source to ensure that the
pump will remain inoperative.
3. Allow the pump to cool if overheated.
4. Check the temperature before opening any covers, plates, or plugs.
5. Close the suction and discharge valves.
6. Vent the pump slowly and cautiously.
7. Drain the pump