background image

Electrical connection

Electrical connection diagram

Fig. 17: Electrical connection diagram

PCB1:

Keyboard board

PCB2:

Control board

PCB3:

Main board

PCB4:

IPM protection board

PCB5:

Condenser board

CM

Compressor

CX1

Condenser, vaporiser fan

CX2

Condenser, condenser fan

FM1

Vaporiser fan

FM2

Condenser fan

LH:

Reactor

MS1

Microswitch alarm (container full)

MS2

Microswitch condensate pump

SM

Swing motor

THCT:

Probe compressor temperature

THEP:

Probe condenser

THOP:

Probe compressor final temperature

THRA:

Probe room temperature

WM

Condensate pump

Colour code:

BK

Black

BR

Brown

BU

Blue

GR

Gray

OR

Orange

R

Red

W

White

Y

Yellow

 

 

 

 

 

17

Содержание RKL 491 DC

Страница 1: ...Assembly and operating instructions Read the instructions prior to performing any task REMKO RKL 491 DC Local inverter room air conditioner in split design 0074 2015 07 Edition 2 en_GB...

Страница 2: ...g inal Read these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject t...

Страница 3: ...d changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transport and packaging 6 1 12 Environmental protection and recycling 6 2 Technical data 7 2 1 Technical data 7 3 Structure and function 8 4 Operati...

Страница 4: ...ay be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This...

Страница 5: ...ts may only be mounted at the points pro vided for this purpose at the factory The units may only be secured or mounted on stable structures walls or floors n Mobile units must be set up securely on s...

Страница 6: ...ion and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate rials Only...

Страница 7: ...unit 2 dB A 45 48 54 Sound power level max IT AT dB A 59 64 Power supply V Hz 230 1 50 Enclosure class indoor unit outdoor unit IP 24 X4 Electr rated power consumption 1 kW 1 31 Electr rated current...

Страница 8: ...by means of a heat exchanger condenser The condensate col lected during cooling operation is transported to the outdoor unit by means of a condensate pump integrated into the indoor unit and evaporat...

Страница 9: ...s the compressor will be activated in max 3 mins 10 Button Temperature setting The desired nominal temperature can be set with the buttons in steps of 1 C between 16 and 30 C 11 Display The display sh...

Страница 10: ...ode DE HUM Position the indoor unit and the outdoor unit in the room that is to be dehumidified 1 Ensure that the indoor unit cannot extract warm air from the outdoor unit 2 Do not hang the outdoor un...

Страница 11: ...information when laying the con nector pipes n The connector pipes may not be jammed in or kinked n There may not be any tension of other mechanical stress exerted on the connector pipes n The pipe in...

Страница 12: ...is not stressed and that the insulation is not damaged in the process Maintain the minimum gaps The air outlets of the indoor and outdoor units may not be blocked Fig 8 Required air circulation 353 mm...

Страница 13: ...th quick release couplings This provides the facility to disconnect the connecting line from the indoor unit for assembly purposes without losing refrigerant DANGER The unit must be disconnected from...

Страница 14: ...y only be disconnected and connected by authorised specialist engineers In doing so the following procedure must be adhered to 1 Switch the unit off 2 Pull the power plug out of the socket 3 Remove th...

Страница 15: ...ended spanner to hold the upper coupling section still Fig 15 NOTICE Never twist the the fixed upper section 12 Screw continuously until the connection is disconnected NOTICE Do not stop screwing in...

Страница 16: ...A B C Fig 15 Unscrew the right hand union nut A Hold to prevent turning B Tighten C Loosen 1 1 Fig 16 Screw on protective caps 1 Protective caps REMKO RKL 16...

Страница 17: ...1 Condenser vaporiser fan CX2 Condenser condenser fan FM1 Vaporiser fan FM2 Condenser fan LH Reactor MS1 Microswitch alarm container full MS2 Microswitch condensate pump SM Swing motor THCT Probe comp...

Страница 18: ...ve Wait for timer period to expire or press I 0 button again The unit is running with Reduced ventilation output Used air or outlet openings soiled or blocked by foreign bodies Clean the openings Remo...

Страница 19: ...y work ensure the equip ment is disconnected from the voltage supply and secured to prevent accidental switch on 1 Fig 18 Remove filter 1 Filter n Clean the equipment using a damp cloth Do not use a j...

Страница 20: ...riods e g during the winter proceed as follows 1 Allow the equipment run for 2 3 hours in cir culation mode This extracts any residual humidity from the unit 2 Shut down the equipment by pressing the...

Страница 21: ...ded view and spare parts lists 11 1 Exploded view indoor unit Fig 19 Exploded view indoor unit We reserve the right to modify the dimensions and design as part of the ongoing technical development pro...

Страница 22: ...number 2 Recessed grip 3 Cover top 4 Exhaust grille 5 Fins 6 Shift lever for fins 7 Back wall 8 Air filter 9 Cover for connecting line 10 Unit base 11 Base plate cpl 12 Conveyor rollers 13 Side cover...

Страница 23: ...necting line cpl 35 Fastening block cpl 36 Condensate drain hose 37 Keypad board 38 Keypad foil 39 Control board 40 IPM protection board 41 Mains cable with plug 42 Motherboard 43 Capacitor board 44 C...

Страница 24: ...0 Back wall On request by providing the serial number 51 Front panel 52 Unit base 53 Covering for fan 54 Condenser fan 55 Fastening for condenser fan 56 Condenser fan motor 57 Condenser 58 Seal Spare...

Страница 25: ...e ground 11 Mounting height 12 Mounting on an external wall with wall bracket 12 Outdoor unit 11 M Maintenance 19 O Operation Circulated air mode 10 Control panel 9 Cooling mode 10 Dehumidifying mode...

Страница 26: ...REMKO RKL 26...

Страница 27: ......

Страница 28: ...t as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is q...

Отзывы: