Safety Instructions

 

 
Extensive tests have been conducted on the material, 
functionality and quality of the REMKO portable air con-
ditioner to ensure that it is a high-performance unit with 
a long service life. 

Hazards may nevertheless arise if the unit is used by 
persons not familiar with its operation or if the unit is not 
used for its intended purpose. 

Please also make sure to follow these safety instruc-
tions.

 

Ensure that the unit is set up at a safe 
distance from flammable materials. 

Do not use the unit if it is lying on its 
side or in any manner deviating from 
these instructions. 

Ensure that the air intake and outlet 
openings are always clear of foreign 
objects. 

Do not insert any foreign objects into 
the air intake or outlet openings. 

Do not set the unit up near curtains 
or drapes. 

Maintain a safety zone of at least 50 
cm around the unit. 

min. 50 cm 

Ensure that the air conditioner is se-
curely placed on a level surface. 
The unit may only be operated in an 
upright position. 

Do not place any heavy or warm ob-
jects on top of the unit. 

Do not set up or operate the unit in rooms containing 
explosion hazards. 

Do not set up or operate the unit if the atmosphere is 
contaminated by oil, sulfur or salt. 

Do not expose the unit to direct streams of water. 

Protect all cables from damage. 

Make sure that all extension cables are suitable in 
terms of capacity, length and intended use. 

This unit may only be connected to a 
correctly installed, grounded and 
fused plug socket. 

230V / 50 Hz; 10A fuse. 

Do not move the unit while in opera-
tion. Wait at least five minutes before 
starting the unit after it has been 
moved. 

This may result in damage to the com-
pressor. 

5 MIN. 

Do not pull on the power cable or 
bend it excessively. 

This may result in damage to the 
cable. 

When unplugging the unit, always pull 
the power plug. Never pull the cable. 

Switch the unit off by pressing the ON/
OFF button. 

Do not switch the unit off by unplug-
ging the power cable. 

Empty the water tank before moving the 
unit. 

230V  10A 

To ensure that the unit operates effec-
tively, place the flexible exhaust hose 
at an upwards incline and do not bend 
it too sharply. 

G

 

When the unit is in operation, do not switch it off 
directly at the power supply by unplugging it as 
this may damage the control circuit and invalidate 
the warranty. Always switch the unit on and off at 
the control panel.

 

Содержание RKL 220

Страница 1: ...REMKO powerful like a bear REMKO RKL 220 RKL 240 Portable Air Conditioner Edition GB M04 Operation Technology Spare Parts ...

Страница 2: ......

Страница 3: ...am 11 Exploded View 12 Spare Part List 13 Wall Lead Through Kit 14 Portable Air Conditioner REMKO RKL 220 REMKO RKL 240 Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes or maintained incorrectly etc or if it is changed without our prior consent Subject to alteratio...

Страница 4: ...the unit in rooms containing explosion hazards Do not set up or operate the unit if the atmosphere is contaminated by oil sulfur or salt Do not expose the unit to direct streams of water Protect all cables from damage Make sure that all extension cables are suitable in terms of capacity length and intended use This unit may only be connected to a correctly installed grounded and fused plug socket ...

Страница 5: ...ed overflow safety mechanism ensure proper operation of the unit This portable air conditioner meets the basic safety and consumer health requirements outlined in the relevant EU regulations It is safe and easy to operate How is the air cooled in the room In a closed loop cycle there is a special medium called a refrigerant This refrigerant transports the excess heat out of the room to be cooled A...

Страница 6: ... is off using the SET button the user can enter the number of hours after which the unit is to be switched on Each time the button is pressed the number of hours is increased by 1 If this function is activated TIMING ON 9 is lit up After the timer has been activated the operating mode and target temperature can be set as de scribed above 2 Unit switches off automatically When the device is on usin...

Страница 7: ...y provides information about the operat ing mode and the fan setting which have been se lected 12 REMOTE SENSOR sensor remote control The unit receives the signals sent from the infrared remote control special accessory for RKL 220 via the REMOTE SENSOR POWER on off THERMO CONTROL MODE TIMER AUTO SWING reset set 1 4 2 5 6 1 Switch the unit on with the On Off button 2 Set the target temperature usi...

Страница 8: ...utput opening on the back side of the unit Slide the deflector piece from the top down into the notches on the side un til it clicks into place With a fix connection to the exhaust hose wall lead through The hose supplied is firmly connected to a wall lead through Lead through kits can be purchased as accessories With a flat nozzle The flat nozzle supplied can be used in two different ways 1 It is...

Страница 9: ...and that there are no kinks 5 Empty the water tank 6 Remove the remaining water via the tube to the left in the opening for the water tank 7 Make sure to replace the sealing cap on the tube If the sealing cap is not replaced water may leak out Prior to longer idle periods Remove the dust filter If the dust filter is only slightly dirty clean off the dust for example with a vacuum cleaner If the du...

Страница 10: ...r tank has not been prop erly inserted Has the tank been placed at an angle in the tank holder Remove tank and reinsert Water tank is full Is the FULL TANK LED lit up Empty tank The unit is either not cooling at all or only cooling a little bit The exhaust hose is bent extended place downwards or blocked Does the cooling performance im prove when the unit is operated without an exhaust hose a filt...

Страница 11: ... g 450 450 Operating range C 20 to 35 20 to 35 Electrical connection V Ph Hz 230 1 50 230 1 50 Power consumption max W 700 710 Nominal current max A 3 0 3 1 Fuse protection suggested A 10 10 Dehumidifying capacity max l h 1 0 1 2 Volume water tank max unit shut down l 3 6 3 2 3 6 3 2 Sound pressure level LpA 1m 2 dB A 54 58 54 58 AUTO SWING range of motion air outlet plate fins 70 70 Fan speeds 3 ...

Страница 12: ...10 11 13 21 20 22 28 27 26 29 31 32 33 43 30 35 39 37 36 40 38 41 42 34 14 15 16 17 18 19 23 25 24 8 Exploded View We reserve the right to make modifications in dimensions and construction in the interests of technical progress ...

Страница 13: ...22 23 Separating plate 1106023 1106023 24 Cover rear 1106024 1106024 25 Condenser 1106025 1106025 26 Labelling control panel 1106052 1106052 27 Cover front 1106053 1106053 28 Control board 1106058 1106058 29 Plate fins vertical 1106029 1106029 30 Mobile holder plate fins 1106042 1106042 31 Plate fins horizontal 1106030 1106030 32 Mounting frame 1106055 1106055 33 Motor plate fins 1106032 1106032 3...

Страница 14: ...es insulate the telescope pipe with a suitable insulation material 3 Place bricks around the telescope pipe in the core hole so that it is aligned with both sides of the wall 4 Attach the safety guard to the outer side of the wall with 4 screws Mount the safety guard paying attention to the position of the rain drainage 5 Insert the back pressure flap inside and attach it with 4 screws as well The...

Страница 15: ......

Страница 16: ...REMKO GmbH Co KG Klima und Wärmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 ...

Отзывы: