Spare Part List 

 

No. 

Designation 

RKL 220 
Ref.-No. 

RKL 240 
Ref.-No. 

Fan motor (circulating air) 

1106001 

1106001 

Capacitor 1,5 µF 

1106002 

1106002 

Capacitor 3,0 µF 

1106003 

1106003 

Capacitor 20,0 µF 

1106048 

1106048 

Sensor (temperature) 

1106005 

1106005 

Cover, top 

1106006 

1106006 

Power board 

1106057 

1106057 

Cover, front 

1106008 

1106008 

Fan housing (upper part) 

1106009 

1106009 

10 

Fan wheel 

1106010 

1106010 

11 

Evaporator 

1106011 

1106045 

12 

Fan housing (lower part) 

1106012 

1106012 

13 

Condensation trap 

1106014 

1106014 

14 

Drainage tube 

1106013 

1106013 

15 

Cover, centre 

1106015 

1106015 

16 

Fan motor (exhaust air) 

1106016 

1106016 

17 

Cover (fan) 

1106017 

1106017 

18 

Fan wheel 

1106018 

1106046 

19 

Fan housing 

1106019 

1106019 

20 

Filter frame 

1106020 

1106020 

21 

Dust filter 

1106021 

1106021 

22 

Side cover, left 

1106022 

1106022 

23 

Separating plate

 

1106023 

1106023 

24 

Cover rear 

1106024 

1106024 

25 

Condenser 

1106025 

1106025 

26 

Labelling (control panel) 

1106052 

1106052 

27 

Cover, front 

1106053 

1106053 

28 

Control board 

1106058 

1106058 

29 

Plate fins, vertical 

1106029 

1106029 

30 

Mobile holder (plate fins) 

1106042 

1106042 

31 

Plate fins, horizontal 

1106030 

1106030 

32 

Mounting frame 

1106055 

1106055 

33 

Motor (plate fins) 

1106032 

1106032 

34 

Cover, bottom 

1106033 

1106033 

35 

Micro-switch 

1106034 

1106034 

36 

Condensation trap 

1106026 

1106026 

37 

Compressor 

1106049 

1106050 

38 

Side cover, right 

1106036 

1106036 

39 

Floater flap 

1106037 

1106037 

40 

Separating plate 

1106038 

1106038 

41 

Guidance (water tank) 

1106039 

1106039 

42 

Water tank, cpl. 

1106040 

1106040 

43 

Transport wheels 

1106041 

1106041 

44 

Infrared-remote control (Standard with RKL 240) 

1613135 

1613135 

not shown  Power cable with plug 

1106043 

1106043 

 

Air hose, cpl. (exhaust) 

1106056 

1106056 

 

Wall lead-through (kit) 

1613110 

1613110 

 

 

 

 

When ordering spare parts please indicate ref.-no. and machine no. (see type plate)!

 

Содержание RKL 220

Страница 1: ...REMKO powerful like a bear REMKO RKL 220 RKL 240 Portable Air Conditioner Edition GB M04 Operation Technology Spare Parts ...

Страница 2: ......

Страница 3: ...am 11 Exploded View 12 Spare Part List 13 Wall Lead Through Kit 14 Portable Air Conditioner REMKO RKL 220 REMKO RKL 240 Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes or maintained incorrectly etc or if it is changed without our prior consent Subject to alteratio...

Страница 4: ...the unit in rooms containing explosion hazards Do not set up or operate the unit if the atmosphere is contaminated by oil sulfur or salt Do not expose the unit to direct streams of water Protect all cables from damage Make sure that all extension cables are suitable in terms of capacity length and intended use This unit may only be connected to a correctly installed grounded and fused plug socket ...

Страница 5: ...ed overflow safety mechanism ensure proper operation of the unit This portable air conditioner meets the basic safety and consumer health requirements outlined in the relevant EU regulations It is safe and easy to operate How is the air cooled in the room In a closed loop cycle there is a special medium called a refrigerant This refrigerant transports the excess heat out of the room to be cooled A...

Страница 6: ... is off using the SET button the user can enter the number of hours after which the unit is to be switched on Each time the button is pressed the number of hours is increased by 1 If this function is activated TIMING ON 9 is lit up After the timer has been activated the operating mode and target temperature can be set as de scribed above 2 Unit switches off automatically When the device is on usin...

Страница 7: ...y provides information about the operat ing mode and the fan setting which have been se lected 12 REMOTE SENSOR sensor remote control The unit receives the signals sent from the infrared remote control special accessory for RKL 220 via the REMOTE SENSOR POWER on off THERMO CONTROL MODE TIMER AUTO SWING reset set 1 4 2 5 6 1 Switch the unit on with the On Off button 2 Set the target temperature usi...

Страница 8: ...utput opening on the back side of the unit Slide the deflector piece from the top down into the notches on the side un til it clicks into place With a fix connection to the exhaust hose wall lead through The hose supplied is firmly connected to a wall lead through Lead through kits can be purchased as accessories With a flat nozzle The flat nozzle supplied can be used in two different ways 1 It is...

Страница 9: ...and that there are no kinks 5 Empty the water tank 6 Remove the remaining water via the tube to the left in the opening for the water tank 7 Make sure to replace the sealing cap on the tube If the sealing cap is not replaced water may leak out Prior to longer idle periods Remove the dust filter If the dust filter is only slightly dirty clean off the dust for example with a vacuum cleaner If the du...

Страница 10: ...r tank has not been prop erly inserted Has the tank been placed at an angle in the tank holder Remove tank and reinsert Water tank is full Is the FULL TANK LED lit up Empty tank The unit is either not cooling at all or only cooling a little bit The exhaust hose is bent extended place downwards or blocked Does the cooling performance im prove when the unit is operated without an exhaust hose a filt...

Страница 11: ... g 450 450 Operating range C 20 to 35 20 to 35 Electrical connection V Ph Hz 230 1 50 230 1 50 Power consumption max W 700 710 Nominal current max A 3 0 3 1 Fuse protection suggested A 10 10 Dehumidifying capacity max l h 1 0 1 2 Volume water tank max unit shut down l 3 6 3 2 3 6 3 2 Sound pressure level LpA 1m 2 dB A 54 58 54 58 AUTO SWING range of motion air outlet plate fins 70 70 Fan speeds 3 ...

Страница 12: ...10 11 13 21 20 22 28 27 26 29 31 32 33 43 30 35 39 37 36 40 38 41 42 34 14 15 16 17 18 19 23 25 24 8 Exploded View We reserve the right to make modifications in dimensions and construction in the interests of technical progress ...

Страница 13: ...22 23 Separating plate 1106023 1106023 24 Cover rear 1106024 1106024 25 Condenser 1106025 1106025 26 Labelling control panel 1106052 1106052 27 Cover front 1106053 1106053 28 Control board 1106058 1106058 29 Plate fins vertical 1106029 1106029 30 Mobile holder plate fins 1106042 1106042 31 Plate fins horizontal 1106030 1106030 32 Mounting frame 1106055 1106055 33 Motor plate fins 1106032 1106032 3...

Страница 14: ...es insulate the telescope pipe with a suitable insulation material 3 Place bricks around the telescope pipe in the core hole so that it is aligned with both sides of the wall 4 Attach the safety guard to the outer side of the wall with 4 screws Mount the safety guard paying attention to the position of the rain drainage 5 Insert the back pressure flap inside and attach it with 4 screws as well The...

Страница 15: ......

Страница 16: ...REMKO GmbH Co KG Klima und Wärmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 ...

Отзывы: