Malfunctions
Fault
Possible cause
Checks
Remedy
The unit does not start or
switches it self off
Power outage, under-
voltage, defective mains
fuse / main switch in off
position
Are all other electrical
installations functioning
correctly?
Check voltage if neces-
sary wait until turned on
again.
Damaged mains cable
Are all other electrical
installations functioning
correctly?
Repair by a specialist
Wait time after switching
on is too short
Have approx. 5 minutes
elapsed since the
restart?
Schedule longer waiting
periods
Temperature outside
operating range.
Are the fans in the indoor
unit and outdoor compo-
nent working correctly?
Take into account the
temperature range for
the indoor unit and out-
door component
Electrical surges caused
by thunderstorms
Have there been light-
ning strikes in the area
recently?
Switch off the mains
breaker and switch it
back on. Have it checked
by a specialist
Fault in external conden-
sation pump
Did the pump shut down
due to a fault?
Check and if necessary
clean the pump
The unit does not
respond to the remote
control
Transmission distance
too far / receiver affected
by interference
Does the indoor unit
beep when pressing a
button?
Reduce the distance to
less than 6 m or change
position
Defective remote control
Is the unit running in
manual mode?
Replace the remote con-
trol
Receiver or transmitter
unit exposed to exces-
sive solar radiation
Does it function correctly
in the shade?
Place the receiver &
transmitter unit in the
shade
Electromagnetic fields
are interfering with trans-
mission
Does it function when
switching off possible
sources of interference?
Signal is not transmitted
when interference
sources are operational
Button in remote control
jammed / two buttons
pressed at same time
Does the “Send” symbol
appear on the display?
Release the button /
press only one button
Batteries in remote con-
trol are flat
Have new batteries been
inserted? Is the display
incomplete?
Insert new batteries
The unit is running with
reduced or without
cooling / heating output
Filter is unclean / air
inlet / outlet blocked by
foreign objects
Have the filters been
cleaned?
Clean the filters