„Heating“ mode
In the heating mode, you can heat the room in
spring or fall. The selected room temperature is set
using the " " and " " keys in 1 °C increments. If
the room temperature is 1 °C below the selected
target temperature, the indoor unit starts to heat
the air in the room. If the set room temperature is
exceeded by approx. 1 °C, the controller will switch
off the heater function. To protect the compressor,
the controller will wait 3 minutes before switching
on the heating mode again. The fan operation
starts only at a temperature of 32 ° C at the heat
exchanger.
Fig. 15: „Heating“ mode
The heating mode has priority!
Turns on the indoor unit to the heating mode,
switch off the other indoor units from which are
in cooling mode, the cooling. During heating
operation can not be cooled.
„FAN“ key
Function
1. Automatic
2. Low
3. Medium
4. High
Automatic function:
<ca. 1,5 °C = low level
> ca. 1,5 °C = middle level
> ca. 3,5 °C = high level
4
3
2
1
FAN
FAN
FAN
FAN
Fig. 16: "Fan" key