Before

 

Starting 

 
Prior to starting, the unit is to be checked to make sure 
that there are no visible defects on the control and 
safety devices, that the unit has been installed correctly 
and that it has been properly connected to the mains. 

Installation requirements 

à

Install unit in a stable position.

 

à

Make sure that air is supplied for combustion. 

à

Make sure that the air can be sucked in and be ex-
hausted freely. 

à

Avoid overpressure and underpressure in the room 
where the unit has been installed. 

à

The waste gas values of the burner are to be 
checked and adjusted properly by authorised experts 
in accordance with the local conditions. 

Power supply 

à

Any additional clauses of the relevant building regu-
lations and technical rules for combustible liquids 
(TRBF 210 and 280) are to be observed. 

à

Only use clean fuel oil EL and diesel, respectively. 

à

Make sure that enough fuel is supplied. 

à

A sufficient quantity of free-flowing fuel oil must be 
available even with low outside temperatures. 

à

Connecting cable extensions may be laid exclusively 
by authorised electricians based on the unit capacity, 
cable length and taking the local terms of use into 
account. 

à

The connection to the mains of the units is to be car-
ried out in accordance with the VDE 0100 regula-
tions to a special supply point with protection device 
against faulty current. 

G

 

Paraffine formation can start even at a temperature 
of 5° C. Adequate measures are to be taken to 
avoid this.

 

Hot air distribution 

The unit is equipped with a high-duty radial fan. It is suit-
able for selective and effective transportation of 
warmed-up air for long distances.  

Air is preferably distributed through pipings or special 
hot air and sheet hoses, respectively. Hot air may be 
distributed only in accordance with the fan capacity of 
the units concerned. 

The possible hose/pipe lengths depend on the resis-
tance on the air side of the used air ducts. 

Please observe the following instructions when hot air 
hoses are to be fitted:

 

à

Please use exclusively those hot air hoses 
(accessories) which have been approved by our 
company. 

à

The inside overlappings on the seams of the hot air 
hoses must run with the air current direction.  

à

Make sure that the hoses and pipes, respectively, 
are safely fastened to the unit’s outgoing air connec-
tion piece.  

à

The pipes and hoses may not have sharp kinks and 
bends in order to avoid heat accumulation. 

à

In the case of increased suction temperatures or re-
sistance on the unit’s outgoing air side, the burner 
can be switched off by the temperature controller 
(TW) during the heating operation for a short time.  

à

When the temperature has fallen the burner is re-
started automatically. 

G

 

While the unit is operating, frequent startings of 
the burner should be avoided. 

G

 

When the temperature is too high on the unit’s out-
going air side, the heating-operation is interrupted 
automatically for a longer period by the STB! 

Starting 

 
Make sure to charge a person with the operation and 
supervision of the unit who has been instructed suffi-
ciently regarding the handlings concerned. 

Starting of device 

1.   Open lock door at back of device. 

2.  Reassure that the operating switch (S1) in switch-

box is put into position „0“ (= OFF). 

3.   Place the room-thermostat in a suitable place. 

The thermostat-feeler may not be exposed directly to 
the hot air current. 

4.   Connect thermostat plug with thermostat socket. 

5.   Connect unit to a suitable and fused mains socket. 

Control lamps for phases and neutral conductor L1, 
L2, L3 and N must light up now. 

Heating operation 

1.   Open all shut-off devices of the fuel supply. 

2.  Preselect desired room temperature on the room 

thermostat. 

The temperature set must be higher than the room 
temperature. 

3.  Put the operating switch in switch-box into position  

„1“ (= heating). 

4.  Please notice: when the room temperature level is 

too low, the burner switches on automatically. The air 
supply fan does not switch on until the set tempera-
ture of the heat-exchanger has been reached.

 

The control lamps for burner and fan must light up 
now. 

5.  Close the door in order to protect the device against 

unauthorised actions. 

The unit runs fully automatically now with the preselected 
temperature.

 

Содержание HTL 150-FB

Страница 1: ...REMKO as strong as an ox REMKO HTL 150 250 FB 2 step Automatic Oil Heater Edition GB M02 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...rams 12 Wiring Diagram 13 Oil Burner 14 Operating instructions Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us...

Страница 4: ...ld resistant down to 20 C below 20 C the de vice switches off when the temperature rises above this temperature it switches on again When the sensor or the capillary tube is damaged or when an overtem...

Страница 5: ...d Please use exclusively those hot air hoses accessories which have been approved by our company The inside overlappings on the seams of the hot air hoses must run with the air current direction Make...

Страница 6: ...STB If the STB has been released make sure to find the reasons why e g unit could not cool down as the electric power has been cut off temperature of blown out air is too high because of inadequate ai...

Страница 7: ...Have the waste gas values of the burner checked regularly by authorised experts For safety reasons we recommend that you con clude a maintenance contract Make sure to store the unit in a dust free an...

Страница 8: ...s sale and com missioning Burner maintenance Make sure that the burner is exclusively maintained by authorized experts Make sure to observe the limit values for waste gas losses according to the relev...

Страница 9: ...0 3N 50 400 3N 50 power take up max entirely unit W 2 640 4 580 4 810 rated current max entirely unit A 6 1 9 3 9 8 power take up min max fan W 960 1 950 2 700 3 900 2 850 4 100 rated current max fan...

Страница 10: ...6 17 18 20 19 21 22 23 11 9 8 46 7 30 29 28 27 26 31 32 33 34 35 36 39 38 40 41 42 43 44 45 25 24 Unit design comb chamber heat exchanger We reserve the right to make modifications in dimensions and c...

Страница 11: ...ttom rear 1105389 1105389 1105389 26 bracket fan 1105390 1105391 1105391 27 fan 1105375 1105377 1105380 28 inlet nozzle 1105376 1105378 1105378 29 suction plate 1105392 1105393 1105393 30 plate rear w...

Страница 12: ...tactor phase sequence relay K7 Auxiliary relay KX5 6 phase sequence relay KB combined regulator M1 fan motor P1 hour counter RT room thermostat socket S1 operating switch S2 burner reset S3 change ove...

Страница 13: ...double socket close to burner S2 burner reset S3 change over switch 1 2 Step SK switch box TW burner temperature monitor WS4 4 pole plug to burner WS7 7 pole plug to burner X3 terminal strip close to...