REMKO HTL 150-FB Скачать руководство пользователя страница 11

11 

Nr. 

Description

 

HTL 150-FB 

EDV-Nr. 

HTL 200-FB 

EDV-Nr. 

HTL 250-FB 

EDV-Nr. 

cover plate, rear 

1105335 

1105335 

1105335 

rosette waste gas connection 

1103023 

1103023 

1103023 

connecting profile 

1105312 

1105312 

1105312 

cover plate, front 

1105336 

1105336 

1105336 

crane eye 

1102554 

1102554 

1102554 

insulation, top 

1105412 

1105412 

1105412 

insulation, center (left/right) 

1105413 

1105413 

1105413 

trim panel, center (left/right) 

1105339 

1105339 

1105339 

trim panel, front (left/right) 

1105411 

1105411 

1105411 

10 

blow-out cone 

1105341 

1105341 

1105341 

11 

assembly part (front/rear) 

1105413 

1105413 

1105413 

12 

assembly part (fuel filter) 

1105342 

1105342 

1105342 

13 

lock door (burner) 

1105382 

1105382 

1105382 

14 

fuel filter with shut-off valves 

1102526 

1102526 

1102526 

15 

oil collector 

1105344 

1105344 

1105344 

16 

base 

1105345 

1105345 

1105345 

17 

assembly part (electric) 

1105346 

1105346 

1105346 

18 

insulation, (bottom) 

1105347 

1105347 

1105347 

19 

deflector (bottom) 

1105385 

1105385 

1105385 

20 

base plate 

1105386 

1105386 

1105386 

21 

deflector (left/right) 

1105387 

1105387 

1105387 

22 

partition panel, front 

1105352 

1105352 

1105352 

23 

blow-out cone 

1103029 

1103029 

1103029 

24 

carrier (fan) 

1105388 

1105388 

1105388 

25 

insulation, (bottom/rear) 

1105389 

1105389 

1105389 

26 

bracket (fan) 

1105390 

1105391 

1105391 

27 

fan 

1105375 

1105377 

1105380 

28 

inlet nozzle 

1105376 

1105378 

1105378 

29 

suction plate 

1105392 

1105393 

1105393 

30 

plate, rear (with grille) 

1105394 

1105395 

1105395 

31 

snap-on cap with lock 

1105302 

1105302 

1105302 

32 

lock door (rear) 

1105398 

1105398 

1105398 

33 

switch-box, cpl. 

1105396 

1105397 

1105397 

34 

assembly part (switch-box) 

1105399 

1105399 

1105399 

35 

insulation, (top/rear) 

1105401 

1105401 

1105401 

36 

main frame, cpl. 

1105402 

1105402 

1105402 

37 

insulation fan 

1105403 

1105403 

1105403 

38 

screw cap 

1103032 

1103032 

1103032 

39 

burner, cpl. 

  948010 

  948510 

  948510 

40 

burner flange 

1108539 

1108539 

1108539 

41 

flange seal 

1108538 

1108538 

1108538 

42 

comb. chamber & heat-exchanger 

1103054 

1103055 

1105381 

43 

waste gas suppressors, (1 set) 

1105404 

1105405 

1105405 

44 

sealing revision cover 

1105406 

1105406 

1105406 

45 

revision cover 

1105407 

1105407 

1105407 

46 

waste gas connection 

1105360 

1105360 

1105360 

47 

sealing waste gas connection 

1103020 

1103020 

1103020 

 

 

 

 

 

not shown   

 

 

 

 

oil preheater 

1105301 

1105301 

1105301 

 

triple combined regulator 

1102562 

1102562 

1102562 

 

connecting cable with 16A plug 

1105362 

1105362 

1105362 

 

thermostat-socket, (angle) 

1102048 

1102048 

1102048 

 

shunt plug 

1101019 

1101019 

1101019 

 

doublesocket 

1105408 

1105408 

1105408 

 

distributorbox 

1105409 

1105409 

1105409 

 

thermostat plug (accessories) 

1101020 

1101020 

1101020 

List of Spare Parts 

Содержание HTL 150-FB

Страница 1: ...REMKO as strong as an ox REMKO HTL 150 250 FB 2 step Automatic Oil Heater Edition GB M02 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...rams 12 Wiring Diagram 13 Oil Burner 14 Operating instructions Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us...

Страница 4: ...ld resistant down to 20 C below 20 C the de vice switches off when the temperature rises above this temperature it switches on again When the sensor or the capillary tube is damaged or when an overtem...

Страница 5: ...d Please use exclusively those hot air hoses accessories which have been approved by our company The inside overlappings on the seams of the hot air hoses must run with the air current direction Make...

Страница 6: ...STB If the STB has been released make sure to find the reasons why e g unit could not cool down as the electric power has been cut off temperature of blown out air is too high because of inadequate ai...

Страница 7: ...Have the waste gas values of the burner checked regularly by authorised experts For safety reasons we recommend that you con clude a maintenance contract Make sure to store the unit in a dust free an...

Страница 8: ...s sale and com missioning Burner maintenance Make sure that the burner is exclusively maintained by authorized experts Make sure to observe the limit values for waste gas losses according to the relev...

Страница 9: ...0 3N 50 400 3N 50 power take up max entirely unit W 2 640 4 580 4 810 rated current max entirely unit A 6 1 9 3 9 8 power take up min max fan W 960 1 950 2 700 3 900 2 850 4 100 rated current max fan...

Страница 10: ...6 17 18 20 19 21 22 23 11 9 8 46 7 30 29 28 27 26 31 32 33 34 35 36 39 38 40 41 42 43 44 45 25 24 Unit design comb chamber heat exchanger We reserve the right to make modifications in dimensions and c...

Страница 11: ...ttom rear 1105389 1105389 1105389 26 bracket fan 1105390 1105391 1105391 27 fan 1105375 1105377 1105380 28 inlet nozzle 1105376 1105378 1105378 29 suction plate 1105392 1105393 1105393 30 plate rear w...

Страница 12: ...tactor phase sequence relay K7 Auxiliary relay KX5 6 phase sequence relay KB combined regulator M1 fan motor P1 hour counter RT room thermostat socket S1 operating switch S2 burner reset S3 change ove...

Страница 13: ...double socket close to burner S2 burner reset S3 change over switch 1 2 Step SK switch box TW burner temperature monitor WS4 4 pole plug to burner WS7 7 pole plug to burner X3 terminal strip close to...

Страница 14: ...ng cross section Loosen socket screw and turn air inlet device into desired posi tion pay attention to the arrows Turn to min reduced burner pressure Turn to max increased burner pressure Secondary ai...

Страница 15: ...he setting of the control cam air vol ume 1 Less air stage 1 Set the blue adjustment lever by moving it anticlockwise to decrease the opening angle If the burner is operating the servomotor turns auto...

Страница 16: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260...