![REMKO GPM 15 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/remko/gpm-15/gpm-15_operation-technology-spare-parts_1438927016.webp)
16
REMKO GPM
Setting the weekly timer
Heating mode (HTG)
With the key KM you arrive at
page 1 of the menu. Now press
key K1 (HTG) in order to select the
heating mode (HTG).
After selection of the menu is
completed, the following decisions
can be made:
AUTO ON
OFF
TIME
K1
K2
K3
K4
PLEASE NOTE: In the present
menu TIME is based on the timer
function. Thus it is a different
TIME function than described in
the preceding section.
HTG - AUTO heating mode
With key K1 (AUTO) the
automatic operation of the
room thermostat takes place;
the operation of the unit in
heating mode depends on
the programming of the HTG
programming timer (read further
below in the handbook for this).
The activation of the AUTO
heating mode is shown on the
display by illumination of the
programming timer display.
In this state the value of the
desired room temperature can
always be changed with the keys
K+ or K-, whereby the adjusted
room temperature is shown on
the display and the information
TEMPERATURE MAN appears.
The value can be selected within
the range provided for the room
temperatures. This status is shown
on the display with the hand
symbol.
With the initial programme
change, the electronic temperature
regulation automatically functions
again in the HTG heating mode.
HTG - ON heating mode
With key K2 (ON) the continuous
and manual operation of the
room thermostat takes place.
The operation of the unit in
the heating mode depends on
the selected room temperature.
The value of the desired room
temperature is shown on the
display (TEMPERATURE MAN); the
flashing signalises the possibility of
changing this value with the keys
K+ and K-.
The value can be selected within
the designated range for the
temperature. After the end of
the pre-adjusted time for the
temperature selection, the display
from the menu mode heating
ON returns to the display of the
operating menu.
The value of the desired room
temperature can be changed with
the keys K+ or K- in this status,
whereby it can be selected within
the pre-determined range for room
temperatures.
The activation of the mode heating
ON is shown on
the display by the disappearance of
the programming timer display.
HTG - OFF heating mode
With key K3 (OFF) the heating
mode is deactivated.
The activation of the heating OFF
mode is shown on the display
through the disappearance of the
heater symbol and the appearance
of the programming timer display.
With the heating OFF mode, the
frost protection function (+ 5°C)
remains switched on.
HTG - TIME (timer) heating mode
With key K4 (TIME) the heating
TIME mode is switched on; in
doing so the operation of the
room thermostat is set to a specific
temperature fur a specific length
of time.
The operation of the unit in the
heating mode depends on the
selected room temperature and on
the time set on the timer.
With key K1 (DURATION) the
adjustment of the time within the
range provided for the timer is
selected; with key K4 (TEMP), on
the other hand, the adjustment
of the desired room temperature
within the room temperature range
provided for the timer is selected.
Both values can be changed after
completion of the selection with
the keys K+ and K-.
With selection of the respective
menu, the default parameters for
the timer function and the room
temperature levels (T1, T2 or T3)
that are shown on the display
are available at that point in time
corresponding to the programming
of the HTG programming timer.
The return to operation takes place
automatically at the end of the
time provided for the selection of
parameters or by pressing the key
KM.
The activation of the TIME heating
mode is shown on the display by
the designation TIMER.
At the end of the adjusted timing
for the timer function, the unit
returns to the heating mode that
was present before the adjustment
of the heating TIME mode.