6
REMKO ELT series
Heating with room thermostat
(Accessories)
The units operate fully
automatically and according to the
respective room temperature.
1. Pull out the strapping plug [2].
2. Connect the plug [3] of the
room thermostat [4] with the
thermostat socket [1] on the
unit.
3. Place the room thermostat [4]
at a suitable location in the
room.
The thermostat sensor must not
be located directly in the warm
air flow and must not be placed
directly on the cold floor.
4. Set the desired room
temperature on the room
thermostat [4].
5. Select the desired power
position on the respective
operating switch.
Operating settings
The operating settings can be
selected via a switch or a cam
switch.
However, a room thermostat is
always required for operation.
s
s
s
Shutdown
Fan
Only the supply air fan operates in
this setting.
Thermostatic regulation and
heating operation are not possible
in this operating mode.
Move the operating switch to the
desired position 1.
3
1
4
1. Move the operating switch to
the “0” position.
The supply air fan runs on to cool
the units and only switches off
after the cooling down phase is
complete.
The fan can switch on and run
several times before the final
shutdown.
2. If the units are inactive for long
periods, disconnect them from
the mains power supply.
ELT 10-6 and ELT 18-9
ELT 3-2
ELT 10-6 / 18-9
ELT 10-6 / 18-9
1st stage
1st stage
2nd stage
2nd stage
3rd stage
ELT 3-2
CAUTION
Never interrupt the power
supply prior to the completion
of the follow-up cooling phase.
There is no warranty claim
for damage to the units from
overheating.
ELT 3-2
ELT 10-6
ELT 18-9
There is no separate ventilation
function for this ELT 3-2.
CAUTION
!