![REMKO ELT 10-6 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/remko/elt-10-6/elt-10-6_operating-and-installation-instructions_1438910015.webp)
15
Technical data
1) Noise level measurement DIN 45635 - 01 - KL 3
( ) INOX design
We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
Series
Symbol
Unit
ELT 3-2 (E)
ELT 10-6 (E)
ELT 18-9 (E)
Nominal heating capacity
P
nom
kW
3.2
10.5
18
Minimum heating power
P
min
kW
2.2
3.5
6
Maximum continuous
heating power
P
max,c
kW
3.2
10.5
18
Switchable heating capacity
kW
2.2 or 3.2
3 x 3.5
3 x 6
Air volume
m
3
/h
350
750
1,000
Power supply
V/Hz
230/1~/50
400/3~N / 50
400/3~N / 50
Max. rated current
A
13.9
14.9
27.5
Max. power consumption
kW
2.25 / 3.25
10.65
18.2
Auxiliary current consumption at
nominal heating power
el
max
kW
3.250
10.650
18.150
Auxiliary current consumption at
minimum heating power
el
min
kW
2.250
3.650
6.150
Auxiliary current consumption in
standby condition
el
SB
kW
0.000
0.000
0.000
Electrical protection (provided by the
customer - slow)
A
16
16
32
Sound pressure level L
pA
1m
1)
dB (A)
46
53
57
Dimensions: L/W/H
mm
400/200/335
675/300/455
740/335/500
Type of room temperature control
with elecrical room temperature control (external)
Weight
kg
6.8
20.0
27.4
EDP no.:
114155 (114165) 114255 (114265) 114305 (114315)