REMKO ELT 10-6 Скачать руководство пользователя страница 4

4

REMKO ELT series

Safety notes

Unit description

The units are portable electric 
heating units for industrial 
applications.  
The units are operated exclusively 
with electric power and have been 
designed in such a way that they 
can be used fully automatically, 
universally and in a straightforward 
manner.

The units are equipped with 
specially enclosed electric heating 
resistors, low noise and low-
maintenance axial fans, safety and 
aftercooler thermostats, a room 
thermostat socket and power cable 
with protective contact plug.

The units conform to the 
fundamental health and safety 
requirements of the appropriate 
EU stipulations.

The units are dependable and offer 
ease of operation.

The units may be used among 
other things for the following:

   Drying newly completed 

buildings

   Spot heating outdoor 

workspaces or fire-proof 
manufacturing facilities and 
halls

   Continuous or temporary room 

heating

   De-icing machines, vehicles and 

non-combustible warehoused 
goods while adhering to the 
relevant safety distances

Always observe the respective local building code and fire prevention 
guidelines as well as the guidelines of the accident prevention and 
insurance associations when using the units.

The units have been subjected 
to extensive material, functional 
and quality inspections prior to 
delivery. However, dangers can 
arise from the units if they are used 
improperly or not as intended by 
untrained personnel!  

Please observe the following notes:

  The personnel tasked with 

operating the units must check 
the units for visible defects on 
the operating and safety devices 
as well as the presence and 
function of the protective devices 
prior to starting work 

Inform the supervisor if defects 
are discovered!

  In the event of defects that 

endanger the operational safety 
of the unit, operation must be 
discontinued immediately

  Observe the respective local 

regulations and the relevant 
electrical safety measures when 
using the units

  Maintain safety distances to 

combustible materials

  An unobstructed air inlet and air 

outlet must be guaranteed at all 
times

  The air outlet must not be 

constricted or equipped with 
pipe or hose lines

  Never insert foreign objects into 

the units

  The units must not be covered 

during operation

  Safety devices must not be 

bypassed or disabled

  The units must not be operated 

in the vicinity of bathtubs, 
showers, swimming pools etc.

  The units must not be operated 

directly below a wall socket

  The units must not be exposed 

to direct jets of water 
e.g. 

pressure washers etc.

  Never allow water to enter the 

units

  The units must not be installed 

or operated in potentially 
flammable or explosive 
environments

   The units must not be installed 

or operated in atmospheres 
containing oil, sulphur or salt

  All electrical cables for the 

units must be protected against 
damage, even damage caused 
by animals

  The units must be set up in 

a stable, horizontal position

Safety devices must not be 

bypassed or disabled.

CAUTION

Содержание ELT 10-6

Страница 1: ...on instructions This product is suitable only for well insulated rooms or for occasional use Edition EN Q03 Read the instructions prior to performing any task ELT 3 2 E ELT 10 6 E ELT 18 9 E REMKO ELT...

Страница 2: ......

Страница 3: ...6 11 Spare parts list for ELT 10 6 11 Exploded view of ELT 18 9 12 Spare parts list for ELT 18 9 13 Maintenance protocol 14 Technical data 15 Contents Carefully read this operating manual prior to co...

Страница 4: ...or not as intended by untrained personnel Please observe the following notes The personnel tasked with operating the units must check the units for visible defects on the operating and safety devices...

Страница 5: ...units must be in the intended horizontal position on their supports at all times during operation Off Fan 1st heating stage 2nd heating stage 3rd heating stage Operating switch ELT 10 6 and ELT 18 9 3...

Страница 6: ...d for operation s s s Shutdown Fan Only the supply air fan operates in this setting Thermostatic regulation and heating operation are not possible in this operating mode Move the operating switch to t...

Страница 7: ...t set the thermostat to a value that is higher than the room temperature If all of the functional checks have been carried out without any findings please contact an authorised service station Trouble...

Страница 8: ...for the units is subject to continuous quality control Only high grade materials are processed the majority of which are recyclable You also contribute to environmental protection by ensuring that you...

Страница 9: ...serve the right to modify the dimensions and design as part of the ongoing technical development process ELT 18 9 HW 1 9 S STB NK TB KL 1 M A1 A2 A1 A2 RT 2 3 L1 L2 L3 N PE L1 L2 L3 N 1 2 3 4 5 K1 K2...

Страница 10: ...xterior cladding ELT 3 2 1103905 14 Back wall 1103913 2a Exterior cladding ELT 3 2 E 1103940 15 Mains cable with plug 1103901 3 Aftercooler thermostat 1104065 16 Strain relief 1101267 4 Temperature li...

Страница 11: ...ing ELT 10 6 1107910 14 Strain relief 1107944 2a Exterior cladding ELT 10 6 E 1107909 15 Strapping plug 1101019 3 Inner casing 1103951 16 Thermostat socket cpl 1101018 4 Protective outlet grille 11039...

Страница 12: ...ies We reserve the right to modify the dimensions and design as part of the ongoing technical development process Exploded view of ELT 18 9 E 1 2 18 23 25 17 20 8 11 19 21 22 24 16 10 3 9 7 6 8 5 13 1...

Страница 13: ...ll 1107921 7 Floor panel 1107950 8 Temperature limiter with probe 1107960 9 Support 1107922 10 Protective hose 1107915 11 Fan blade 1101153 12 Drive clutch 1103956 13 Fan motor 230 V 1101254 14 Back w...

Страница 14: ...5 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Unit to be maintained only by authorised specialists in accordance with the statutory regulat...

Страница 15: ...Hz 230 1 50 400 3 N 50 400 3 N 50 Max rated current A 13 9 14 9 27 5 Max power consumption kW 2 25 3 25 10 65 18 2 Auxiliary current consumption at nominal heating power elmax kW 3 250 10 650 18 150 A...

Страница 16: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: