Unit description

Operation

The units can be switched on and 
off with the ON/OFF button.
The LED of the last selected mode 
lights up in the control panel.
The recirculation fan draws in the 
humid room air via the inlet grille 
with filter, condenser and follow-
ing adsorption rotor.

In the internal regeneration circuit, 
the air flows across a heating ele-
ment, dries the adsorption rotor 
and passes the humid air through 
the condenser. 

On the cooler condenser, heat is 
removed from the room air and 
cooled to below dew-point. The 
water vapour contained in the 
room air deposits as condensate. 

Depending on the room air tem-
perature and relative humidity, 
the condensed water constantly 
drips through the integrated drain 
connection into the condensate 
container located below.
The conditioned drier air continu-
ously mixes with the room air. Due 
to the constant circulation of the 

room air through the unit, the 
relative humidity in the room is 
gradually reduced to the required 
humidity (45% relative humidity). 

A float switch in the condensate 
container interrupts dehumidifica-
tion via a microswitch when the 
container is full. The units switch 
off with an audible signal
(5x) and the „FULL TANK“ indica-
tor light illuminates on the control 
panel. This does not extinguish 
until the emptied condensate con-
tainer is refitted. The units return 
to the previously selected mode. 

In an unsupervised continuous 
mode with external condensate 
connection, the produced 
condensate is continuously drained 
via a hose connection on the 
condensate container.

The units are designed for 
universal and problem-free 
dehumidification.

Owing to their compact size, they 
are easy to transport and install.

The units operate according to the 
adsorption principle and are pro-
vided with ioniser, low noise and 
maintenance recirculation fans as 
well as a power cord with plug.

The fully automatic control, the 
condensate container with inte-
grated overflow protection and the 
drain connection for direct con-
densate discharge ensure trouble-
free operation.

The units comply with the 
fundamental safety and health 
requirements of the pertinent EU 
directives.

The units are reliable and easy to 
operate.

The units are used wherever 
dehumidification is necessary and 
consequential damage (e.g. due to 
mould formation) is to be avoided. 

The units are also suitable for 
drying and dehumidification of:

   Living rooms, bedrooms, 

shower or cellar rooms, lofts

   Utility rooms, weekend homes, 

caravans

   Museums, archives, laboratories 

   Wellness areas, washrooms and 

changing rooms, etc.

   Garages, store rooms

The air flow is cooled on its way through or via the condenser to 
below the dew point. The water vapour condenses and is collected 
in a condensate trap and discharged.

saturated air

condenser

condensate container

humid  

room air

regenerative 
heating element

adsorption rotor

  dehumidified 

room air

Содержание ASF 100

Страница 1: ...Edition GB T12 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...allation or on the unit Subject to changes errors and typographical errors excepted Unit description 4 Installation 5 Safety information 6 Commissioning 6 Decommissioning 9 Unit transport 9 Care and m...

Страница 4: ...ed The units return to the previously selected mode In an unsupervised continuous mode with external condensate connection the produced condensate is continuously drained via a hose connection on the...

Страница 5: ...on is achieved when the units are installed about 1 m above the ground The room to be dried or dehu midified must always be closed from the ambient atmosphere Open windows doors etc as well as frequen...

Страница 6: ...the switch off timer for 2 4 or 8 hours AUTO SWING This button is used to activate the automatic swing mode of the air directing flap IONIC This button is used to switch on the ioniser for enriching...

Страница 7: ...ted mode MODE IONIC and AUTO SWING is active when the unit is switched on NORMAL This is the comfort mode The unit regulates according to time 12 hours or on reaching the preset humidity the dehu midi...

Страница 8: ...g etc IONISER The unit has an ioniser genera tor for the generation of negative ions A high concentration of negative ions occurs e g in mountainous regions at waterfalls and in forests and the air we...

Страница 9: ...tion to subsequently dripping condensate Prior to possible storage the units must be cleaned thoroughly and dried For storage purposes the units should be covered with plastic sheeting and stored in a...

Страница 10: ...the plug from the power socket 3 Pull the air inlet grille out of the unit at the recessed grip G ATTENTION The units must not be used without air inlet grille fitted G All moving parts are provided...

Страница 11: ...The FULL TANK indicator light must not light up Check the microswitch of the condensate container Check for free air flow Overheating Check the miniature fuse on the control pcb The unit operates but...

Страница 12: ...operated by suitably trained persons who are familiar with the operation of the unit The manufacturer is not liable for any damage attributed to failure to observe the manufacturer s instructions or...

Страница 13: ...13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Type of unit Serial number 1 2 3 4 5 6 7 8 9 10...

Страница 14: ...nt Heating element Thermal fuse Rear Heating element Heating element Transformer Output Transformer Input Control panel Thermostat Heating element Fan Circulation air Fan Regeneration circuit Adsorpti...

Страница 15: ...output l day 8 7 at 20 C 70 relative humidity l day 8 0 at 15 C 60 relative humidity l day 7 0 Max air volume flow m3 h 150 Condensate container capacity Litre 3 0 Power supply V 230 1 Frequency Hz 50...

Страница 16: ...to date This has given us the reputation of being more than just a good reliable sup plier REMKO a partner that helps solve problems Sales REMKO not only has an extensive sales network in Germany and...

Отзывы: