4.  Clean the air inlet grille with 

warm water or a vacuum 
cleaner. 

5.  A heavily clogged grille with 

filter can be washed in a warm 
soap solution (maximum 40°C).  
Subsequently rinse thoroughly 
with clear water and allow to 
dry!

6.  It must be ensured that the grille 

with filter is completely dry and 
undamaged prior to refitting. 

NOTE

Heavily fouled or damaged air 
inlet grilles must be replaced 
with new ones.
Only original spare parts must 
be used.

Filter cleaning

The unit is provided with an inte-
grated air filter to prevent damage. 

To prevent a reduction in 
performance and faults, the air 
inlet grille with filter must be 
checked as required, however at 
least once a week and cleaned if 
necessary. 

1.  Switch off the unit with the 

button. 

Note the after-running 

time!

2.  Disconnect the plug from the 

power socket. 

3.  Pull the air inlet grille out of the 

unit at the recessed grip [G].

ATTENTION

The units must not be used 
without air inlet grille fitted! 

G

All moving parts are provided 
with low-maintenance permanent 
lubrication. 

   Observe regular care and main-

tenance intervals.

   Depending on the particular 

operating conditions, the units 
should be tested by an expert 
for reliable operation as neces-
sary, however at least once a 
year.

   Only clean the units dry or with 

a moist cloth 

Do not use a jet of water! 

   Do not use caustic cleaning 

agents or those containing 
solvents. 

   Only use suitable cleaning 

agents to remove heavy 
fouling.

   Regularly check the air inlet and 

outlet grilles for fouling. 

Clean or replace if necessary!

Care and maintenance

NOTE

Regular care and maintenance 
is a basic precondition for a 
long useful life and trouble-
free operation of the unit.

ATTENTION

Before carrying out all work 

on the units, the mains plug 

must be disconnected from the 

power socket.

Содержание ASF 100

Страница 1: ...Edition GB T12 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...allation or on the unit Subject to changes errors and typographical errors excepted Unit description 4 Installation 5 Safety information 6 Commissioning 6 Decommissioning 9 Unit transport 9 Care and m...

Страница 4: ...ed The units return to the previously selected mode In an unsupervised continuous mode with external condensate connection the produced condensate is continuously drained via a hose connection on the...

Страница 5: ...on is achieved when the units are installed about 1 m above the ground The room to be dried or dehu midified must always be closed from the ambient atmosphere Open windows doors etc as well as frequen...

Страница 6: ...the switch off timer for 2 4 or 8 hours AUTO SWING This button is used to activate the automatic swing mode of the air directing flap IONIC This button is used to switch on the ioniser for enriching...

Страница 7: ...ted mode MODE IONIC and AUTO SWING is active when the unit is switched on NORMAL This is the comfort mode The unit regulates according to time 12 hours or on reaching the preset humidity the dehu midi...

Страница 8: ...g etc IONISER The unit has an ioniser genera tor for the generation of negative ions A high concentration of negative ions occurs e g in mountainous regions at waterfalls and in forests and the air we...

Страница 9: ...tion to subsequently dripping condensate Prior to possible storage the units must be cleaned thoroughly and dried For storage purposes the units should be covered with plastic sheeting and stored in a...

Страница 10: ...the plug from the power socket 3 Pull the air inlet grille out of the unit at the recessed grip G ATTENTION The units must not be used without air inlet grille fitted G All moving parts are provided...

Страница 11: ...The FULL TANK indicator light must not light up Check the microswitch of the condensate container Check for free air flow Overheating Check the miniature fuse on the control pcb The unit operates but...

Страница 12: ...operated by suitably trained persons who are familiar with the operation of the unit The manufacturer is not liable for any damage attributed to failure to observe the manufacturer s instructions or...

Страница 13: ...13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Type of unit Serial number 1 2 3 4 5 6 7 8 9 10...

Страница 14: ...nt Heating element Thermal fuse Rear Heating element Heating element Transformer Output Transformer Input Control panel Thermostat Heating element Fan Circulation air Fan Regeneration circuit Adsorpti...

Страница 15: ...output l day 8 7 at 20 C 70 relative humidity l day 8 0 at 15 C 60 relative humidity l day 7 0 Max air volume flow m3 h 150 Condensate container capacity Litre 3 0 Power supply V 230 1 Frequency Hz 50...

Страница 16: ...to date This has given us the reputation of being more than just a good reliable sup plier REMKO a partner that helps solve problems Sales REMKO not only has an extensive sales network in Germany and...

Отзывы: