REMKO ASF 100 Скачать руководство пользователя страница 12

12

REMKO ASF 100

Customer service and 

warranty

A precondition for any war-
ranty claims is that the dealer or 
his customer has completed and 
returned the enclosed 

“Warranty 

document”

 to REMKO GmbH & 

Co. KG. 

The units were repeatedly tested 
for perfect functioning at the 
factory.  
If malfunctions should occur 
that cannot be remedied by 
troubleshooting, your specialised 
dealer or contract partner should 
be contacted.

Intended use

Disposal of packaging

Think of the environment when 
disposing of the packaging 
material. 
Our units are carefully packed for 
transport and delivered in sturdy 
cardboard packaging on a wooden 
pallet if necessary.  
The packaging materials are 
environmentally-friendly and can 
be recycled.
By reusing packaging material, 
you make a valuable contribution 
towards waste reduction and the 
conservation of raw materials.

Only dispose of packaging mate-
rial at the facilities provided.

The units are designed and 
equipped for drying and dehumidi-
fication purposes.
The units must not be used for any 
other purposes. 

The units must only be operated 
by suitably trained persons who 
are familiar with the operation of 
the unit. 

The manufacturer is not liable for 
any damage attributed to failure 
to observe the manufacturer‘s 
instructions or applicable statu-
tory requirements or unauthorised 
changes to the unit.

NOTE

Any other operation other than 
that described in these operat-
ing instructions is not permit-
ted.
Non-observance will result in 
all liability being disclaimed 
and render warranty entitle-
ments null and void.

NOTE

Only authorised specialists 
may carry out adjustments and 
maintenance.

Environmental 

protection and 

recycling

Disposal of old unit

This unit must not be disposed of 
together with normal household 
waste but must be must be taken 
to a special collection point for 
recycling electrical and electronic 
equipment.
The materials can be reused ac-
cording to their marking.
Reusing or recycling materials and 
old appliances makes an important 
contribution towards protecting 
the environment.
To find out about your nearest dis-
posal facilities, contact your local 
authorities.

ATTENTION

Copyright

Any copying of this docu-
ment in whole or part or use 
for purposes other than the 
intended is strictly forbid-
den without the prior written 
permission of 

REMKO GmbH 

& Co. KG

.

Содержание ASF 100

Страница 1: ...Edition GB T12 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...allation or on the unit Subject to changes errors and typographical errors excepted Unit description 4 Installation 5 Safety information 6 Commissioning 6 Decommissioning 9 Unit transport 9 Care and m...

Страница 4: ...ed The units return to the previously selected mode In an unsupervised continuous mode with external condensate connection the produced condensate is continuously drained via a hose connection on the...

Страница 5: ...on is achieved when the units are installed about 1 m above the ground The room to be dried or dehu midified must always be closed from the ambient atmosphere Open windows doors etc as well as frequen...

Страница 6: ...the switch off timer for 2 4 or 8 hours AUTO SWING This button is used to activate the automatic swing mode of the air directing flap IONIC This button is used to switch on the ioniser for enriching...

Страница 7: ...ted mode MODE IONIC and AUTO SWING is active when the unit is switched on NORMAL This is the comfort mode The unit regulates according to time 12 hours or on reaching the preset humidity the dehu midi...

Страница 8: ...g etc IONISER The unit has an ioniser genera tor for the generation of negative ions A high concentration of negative ions occurs e g in mountainous regions at waterfalls and in forests and the air we...

Страница 9: ...tion to subsequently dripping condensate Prior to possible storage the units must be cleaned thoroughly and dried For storage purposes the units should be covered with plastic sheeting and stored in a...

Страница 10: ...the plug from the power socket 3 Pull the air inlet grille out of the unit at the recessed grip G ATTENTION The units must not be used without air inlet grille fitted G All moving parts are provided...

Страница 11: ...The FULL TANK indicator light must not light up Check the microswitch of the condensate container Check for free air flow Overheating Check the miniature fuse on the control pcb The unit operates but...

Страница 12: ...operated by suitably trained persons who are familiar with the operation of the unit The manufacturer is not liable for any damage attributed to failure to observe the manufacturer s instructions or...

Страница 13: ...13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Type of unit Serial number 1 2 3 4 5 6 7 8 9 10...

Страница 14: ...nt Heating element Thermal fuse Rear Heating element Heating element Transformer Output Transformer Input Control panel Thermostat Heating element Fan Circulation air Fan Regeneration circuit Adsorpti...

Страница 15: ...output l day 8 7 at 20 C 70 relative humidity l day 8 0 at 15 C 60 relative humidity l day 7 0 Max air volume flow m3 h 150 Condensate container capacity Litre 3 0 Power supply V 230 1 Frequency Hz 50...

Страница 16: ...to date This has given us the reputation of being more than just a good reliable sup plier REMKO a partner that helps solve problems Sales REMKO not only has an extensive sales network in Germany and...