Portable dehumidifierwith adsorption rotor
Operation · Technology · Spare parts
Страница 1: ...Edition GB T12 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation Technology Spare parts...
Страница 2: ......
Страница 3: ...allation or on the unit Subject to changes errors and typographical errors excepted Unit description 4 Installation 5 Safety information 6 Commissioning 6 Decommissioning 9 Unit transport 9 Care and m...
Страница 4: ...ed The units return to the previously selected mode In an unsupervised continuous mode with external condensate connection the produced condensate is continuously drained via a hose connection on the...
Страница 5: ...on is achieved when the units are installed about 1 m above the ground The room to be dried or dehu midified must always be closed from the ambient atmosphere Open windows doors etc as well as frequen...
Страница 6: ...the switch off timer for 2 4 or 8 hours AUTO SWING This button is used to activate the automatic swing mode of the air directing flap IONIC This button is used to switch on the ioniser for enriching...
Страница 7: ...ted mode MODE IONIC and AUTO SWING is active when the unit is switched on NORMAL This is the comfort mode The unit regulates according to time 12 hours or on reaching the preset humidity the dehu midi...
Страница 8: ...g etc IONISER The unit has an ioniser genera tor for the generation of negative ions A high concentration of negative ions occurs e g in mountainous regions at waterfalls and in forests and the air we...
Страница 9: ...tion to subsequently dripping condensate Prior to possible storage the units must be cleaned thoroughly and dried For storage purposes the units should be covered with plastic sheeting and stored in a...
Страница 10: ...the plug from the power socket 3 Pull the air inlet grille out of the unit at the recessed grip G ATTENTION The units must not be used without air inlet grille fitted G All moving parts are provided...
Страница 11: ...The FULL TANK indicator light must not light up Check the microswitch of the condensate container Check for free air flow Overheating Check the miniature fuse on the control pcb The unit operates but...
Страница 12: ...operated by suitably trained persons who are familiar with the operation of the unit The manufacturer is not liable for any damage attributed to failure to observe the manufacturer s instructions or...
Страница 13: ...13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Type of unit Serial number 1 2 3 4 5 6 7 8 9 10...
Страница 14: ...nt Heating element Thermal fuse Rear Heating element Heating element Transformer Output Transformer Input Control panel Thermostat Heating element Fan Circulation air Fan Regeneration circuit Adsorpti...
Страница 15: ...output l day 8 7 at 20 C 70 relative humidity l day 8 0 at 15 C 60 relative humidity l day 7 0 Max air volume flow m3 h 150 Condensate container capacity Litre 3 0 Power supply V 230 1 Frequency Hz 50...
Страница 16: ...to date This has given us the reputation of being more than just a good reliable sup plier REMKO a partner that helps solve problems Sales REMKO not only has an extensive sales network in Germany and...