Technical Data 

Any mode of operation other than specified in these operating instructions is not permissible! 

 

Failing to observe it causes the customer to lose all rights to guarantee or damage claims.

 

 

Any claims under guarantee regarding materials can be accepted only when the orderer or his customer has  

filled in completely the 

“guarantee certificate”

 which is enclosed with every REMKO-device and has  

returned it to REMKO GmbH & Co. KG in due time after the unit’s sale and commissioning. 

 

Model 

 

AMT 60-E 

AMT 90-E 

Working range - temperature 

°C 

3 - 32   

3 - 32 

Working range - humidity

 

% r.h. 

40 - 100  

40 - 100  

Dehumidifying capacity, max.  

l/day 

64 

93 

Dehumidifying capacity at 30°C / 80% r.h  

l/day 

54,2 

79,8 

Dehumidifying capacity at 20°C / 70% r.h. 

l/day 

34,9 

43,1 

Dehumidifying capacity at 10°C / 60% r.h. 

l/day 

11,3 

16,3 

Capacity water container 

litres 

7,5 

––––– 

Cooling capacity at 5°C t

v

 / 45°C t

k

 

kW 

2,86 

4,36 

Air volume 

m³/h 

765  

1050 

Refrigerant (FCKW -free) 

 

R 407 C 

R 407 C 

Refrigerant quantity 

575  

1600 

Power supply  1~ 

230 

230 

Frequency 

Hz 

50 

50 

Rated current consumption, max. 

4,1 

6,9 

Power consumption, max. 

kW 

0,94  

1,56 

Power consumption at 20°C / 70% r.F. 

kW 

0,691 

0,978 

Fuse protection (required) 

10 

16 

Sound pressure level L

pA 

1m

 

1)

 

dB (A) 

60 

68 

Dimensions                       total depth 

mm 

720 (635)  

700 (630) 

                                          total width 

mm 

590 

740 

                                          total height 

mm 

880 (720) 

970 (855) 

Weight 

kg 

48  

63 

 

 

 

 

1) Noise measuring  DIN 45635 - 13 - KL 3 

 

 

 

( ) Dimensions without transport handle 

 

 

 

Содержание AMT 60-E

Страница 1: ...Operation Technology Spare Parts Edition GB M02 REMKO powerful like a bear REMKO AMT 60 E 90 E Mobile Dehumidifier...

Страница 2: ......

Страница 3: ...er REMKO AMT 60 E AMT 90 E G Always keep these operating instructions near or on the unit G Contents page Air Dehumidification 4 Safety Instructions 6 Unit Description 6 Working Range 7 Installation 7...

Страница 4: ...kg of dry air absolute water content 1 m of air weighs approx 1 2 kg at 20 C Depending on the temperature each kg of air can only absorb a defined quantity of water vapour When this quantity has been...

Страница 5: ...n the other hand energy is re leased when gas is liquefied and this energy is called condensation heat The energy rate of evaporation and condensation heat is identical For water this is 2250 kJ kg 4...

Страница 6: ...rdance with the legal or local prescriptions Important Tip Regarding Recycling Unit Description These unit have been designed for automatic universal and problem free air dehumidification Thanks to th...

Страница 7: ...ce depends exclusively upon the design of the room the room temperature the relative humidity and the correct observance of the setup instructions The dehumidification performance increases with the r...

Страница 8: ...socket 230V 1 50 Hz fuse 16 A 2 Put main switch into position I Green control lamp operation is lit up 3 Please note the unit is switched on time delayed and then goes into the continuous operation mo...

Страница 9: ...safe transport 1 Switch off the unit prior to changing its place and to remove the mains plug from the plug socket 2 After that empty the condensate container 3 Make sure to transport and store the u...

Страница 10: ...there are any operating troubles check the unit according to the following listing The unit does not start Control or check operating switch The green control lamp must be lit Check connection to the...

Страница 11: ...difying capacity max l day 64 93 Dehumidifying capacity at 30 C 80 r h l day 54 2 79 8 Dehumidifying capacity at 20 C 70 r h l day 34 9 43 1 Dehumidifying capacity at 10 C 60 r h l day 11 3 16 3 Capac...

Страница 12: ...to make modifications in dimensions and construction in the interests of technical progress 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 20 19 17 18 21 22 23 25 26 27 28 29 30 32 33 31 35 36 37 38 34 39 11 24...

Страница 13: ...mp green 1105514 20 running hour meter 1105515 21 main switch 1102248 22 main fuse 1105561 23 fuse holder 1105560 24 electric cable 1101076 25 cable relief 1101047 26 axle 1105516 27 wheel 1102155 28...

Страница 14: ...1 12 13 14 15 16 18 20 21 22 24 19 25 26 27 29 28 30 31 32 34 33 35 37 38 36 17 7 23 39 We reserve the right to make modifications in dimensions and construction in the interests of technical progress...

Страница 15: ...amp red 1105513 19 control lamp green 1105514 20 running hour meter 1105515 21 main switch 1102248 22 main fuse 1105561 23 fuse holder 1105560 24 electric cable 1101076 25 cable relief 1101047 26 elec...

Страница 16: ...ensor red R2 Temperature sensor blue S1 Main switch S2 Micro switch water container Y1 Solenoid valve MAINS COMPR VALVE FAN COND NTC EVAP NTC FAIL LAMP 1 2 3 4 5 6 7 8 20 21 22 23 24 25 CONTROL BOARD...

Страница 17: ...erature sensor red R2 Temperature sensor blue S1 Main switch Y1 Solenoid valve MAINS COMPR VALVE FAN COND NTC EVAP NTC FAIL LAMP 1 2 3 4 5 6 7 8 20 21 22 23 24 25 H2 green S1 F1 8 2 A 5 2 4 1 C S R h...

Страница 18: ...13 14 15 16 17 18 19 20 Model Model No Device must be maintained according to legal regulations by authorised personnel only Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature S...

Страница 19: ......

Страница 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260...

Отзывы: