©2017 Pinnacle Climate Technologies
13
Vent-Free Gas Heater User’s Manual
INSTALLING THE FAN (OPTIONAL)
1. Disconnect the wall mounted heater from the gas supply and
remove it from the wall before installing the fan accessory.
Contact a qualified service person to do this.
2. Remove the fan knock-out panel using a screwdriver (see Fig.
5). Attach the fan to the rear panel of the heater using the four
provided screws.
NOTE:
Ensure the rocker switch is positioned in the upper right
corner. (see Fig. 6).
3. This fan is equipped with manual ON - OFF switch (see Fig. 7).
Set the rocker switch to “I” for manual ON, allowing the fan to
continuously run until the rocker switch is returned to the OFF
“O” position.
NOTE:
If any of the original wire supplied with the heater must be
replaced, a wire of at least an equal temperature rating must be
used. Refer to Fig. 8 for the wiring diagram.
Electrical grounding instructions: This
appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-
prong receptacle (See Fig. 4).
WARNING
Fig. 5—Knock-out Panel
Fig. 6—Attaching the Fan
Installation (cont.)
Fig. 4—Grounded Three-
Prong Receptacle
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after
servicing.
CAUTION
Rocker Switch
Fig. 7—Operating the Fan
Fig. 8—Fan Wiring Diagram
Rocker Switch