21

Markers

Code no.

Description

Boiler body + Accessories

Base frame

1

8229-8900

Complete frame 7-8 sections

1

8229-8901

Complete frame 9-10 sections

1

8229-8902

Complete frame 11-12 sections

1

8229-8903

Complete frame 13-14 sections

2

8229-8940

Complete rear section

3

8229-0029

Normal intermediate section

4

8229-0030

Special intermediate section

5

8229-8941

Complete front section

6

8005-0200

Nipple

6.1

9430-5027

Nipple greasing product

7

8229-8919

Assembly rod 425

7

8229-8920

Assembly rod 620

7

8229-8921

Assembly rod 784

8

9754-0120

Spring

9

9752-5232

Mounting square

10

9508-6032

Glass fibre cord ø 10 mm (metre)

10.1

9428-5095

Tube of silicon mastic

11

8229-8923

Outlet pipe + seal, 7 to 10 sections

11

8229-8918

Outlet pipe + seal, 11 to 14 sections

12

8104-8965

Return col seal, 7 to 10 sections

12.1

8229-8922

Return col seal, 11 to 14 sections

13

9501-4135

Gasket 12x120x4

14

8202-0028

2" 1/2 plug with 1/2" opening

14.1

8202-0049

Plug 2 1/2"-1/2"-USA+NL

14.2

9494-8080

Nipple N241-1/2"x1/4"

15

8013-0028

Solid plug 2" 1/2

16

8500-0027

Sensor tube

17

9758-1286

Spring for pocket

17.1

9536-5613

Contact spring for thimble tube

18

8229-8911

Complete combustion chamber door, no opening

18

8229-8943

Complete 10 mm combustion chamber door with 
opening on request

18

8229-8947

Complete 15 mm combustion chamber door with 
opening on request

18.1

9495-0050

Plug 1/4"

19

8229-0532

Plate for combustion chamber door, no opening

19

8229-0546

Plate for combustion chamber door with opening ø 
135

19

8339-0508

Plate for combustion chamber door with opening ø 
175

19

8229-0531

Plate for combustion chamber door with opening ø 
190

19

8229-0533

Plate for combustion chamber door with opening ø 
240

19

8339-0509

Plate for combustion chamber door with opening ø 
250

19

8229-0534

Plate for combustion chamber door with opening ø 
290

19

8229-0548

Plate for combustion chamber door with opening 
on request

19

8229-0548

Plate for combustion chamber door with opening 
on request

20

9755-0258

Height converter, insulation

21

9755-0259

Furnace door guard

22

9755-0260

Furnace door insulation

23

8229-0204

Hinge

24

9756-0213

Hinge pin for combustion chamber door

25

8229-0205

Hinge for combustion chamber door

25.1

8229-8944

Hinge unit

26

8229-0025

Ramp

27

9757-0027

Inspection flange

27.1

8015-7700

Vi seals

28

9501-0080

Flame detection cell seal

29

8229-8905

Complete sweeping door, right

30

8229-8906

Complete sweeping door, left

31

9755-0256

Insulation, sweeping door

32

9755-0257

Inner protection, sweeping door

33

8229-0202

Hinge for sweeping door

34

9756-0214

Hinge pin for sweeping door

35

8229-8907

Complete flue gas box

36

8229-8908

Complete right-hand cleaning trap

37

8229-8909

Complete left-hand cleaning trap

38

8229-8916

Flue gas nozzle ø 250 - 7 to 10 sections

38

8229-8917

Flue gas nozzle ø 250 - 11 to 14 sections

40

8229-0010

Upper baffle plate, width 190 mm

40.1

8229-0022

Additional upper baffle plate, width 190 mm

41

8229-0011

Upper baffle plate, width 240 mm

41.1

8229-0023

Additional upper baffle plate, width 240 mm

42

8229-0012

Lower baffle plate

42.1

8229-0024

Additional upper baffle plate

Flow switch

43

8802-4703

Flow controller P 420-7

43

8802-4707

Flow controller P 420-8

43

8802-4710

Flow controller P 420-9

43

8802-4712

Flow controller P 420-10

43

8802-4722

Flow controller P 420-11

Markers

Code no.

Description

Содержание P 420

Страница 1: ...Remeha P 420 Fuel oil gas boilers Technical instructions English 06 04 06 63190 UK...

Страница 2: ...s for connecting the boiler to the heating circuit 10 3 Filling the system 11 4 Sludge removal 11 Chimney connection 12 1 Flue size 12 2 Chimney connection 12 Fuel oil or gas connections 13 Electrical...

Страница 3: ...engineering practice as requested in article 3 3 of the directive 97 23 EC it is certified by compliance with the directives 90 396 EC 92 42 EC 73 23 EC and 89 336 EC Warning The boiler shall be asse...

Страница 4: ...ned for connecting to a flue pipe which require a separate automatic fuel oil or gas burner The useful power of P 420 boilers is between 300 and 780 kW Models available Boiler with control panel which...

Страница 5: ...43 3 511 4 511 4 613 6 613 6 681 8 681 8 761 4 761 4 818 2 818 2 886 4 Number of sections 8 9 10 11 12 13 14 Water capacity l 366 409 452 495 538 581 624 Water resistance T 10K mbar 37 55 86 105 136 1...

Страница 6: ...plugged Boiler type P 420 8 P 420 9 P 420 10 P 420 11 P 420 12 P 420 13 P 420 14 A 250 250 250 300 300 300 300 B 2 1 2 2 1 2 2 1 2 3 3 3 3 C 135 175 190 240 250 290 or Plain plate D 235 235 235 254 2...

Страница 7: ...loor can support the weight of the boiler when it is fitted for operation If the boiler location is not determined precisely leave enough space around the boiler to facilitate monitoring and maintenan...

Страница 8: ...e particularly corrosive These compounds are present for example in aerosol sprays paints solvents cleaning products washing products detergents glues snow clearing salts etc Therefore Do not suck in...

Страница 9: ...Flow switch 6 Air separator 7 Automatic bleed valve 9 Isolation valve 10 3 way mixing valve 11 Boiler pump 12 Sludge decanting pot particularly recommended on older installations 13 Flush valve 14 Wa...

Страница 10: ...the following formulae Nominal water flow Qn 0 86 Pn 20 Minimum flow Qmin 0 86 Pn 45 this flow also corresponds with the minimum recycle flow in the boiler Maximum water flow Qmax 0 86 Pn 5 Qn flow in...

Страница 11: ...y to an expansion vessel which opens out onto the air the system must include manual bleeder valves in addition to automatic bleeder valves with the capability to bleed the system by themselves when i...

Страница 12: ...tom of the chimney The use of a draught moderator is recommended as well 1 Flue size Refer to applicable regulations while determining the size of the flue Please note that P 420 boilers have pressuri...

Страница 13: ...lation of the burner door 1 Max attachment diameter Max B 290 mm Max B 330 mm with 4 fastenings at 15 or 45 Refer to the instructions supplied with the burner Electrical connections ZRefer to the conn...

Страница 14: ...d as soon as required and as the chimney at least once a year or more depending upon applicable regulations and specific needs Cut the power supply to the boiler Remove the upper front panel Open the...

Страница 15: ...am below The 8 figure part number of the baffle plate is moulded into the metal Flue ways P 420 8 P 420 9 P 420 10 P 420 11 P 420 12 P 420 13 P 420 14 Upper 8229 0010 and 8229 0022 2 x 8229 0010 2 x 8...

Страница 16: ...leaning hatches 2 Cleaning the casing material Use a soapy solution and a sponge only Rinse with clean water and dry with chamois leather or a soft cloth 3 Precautions required in the case of long boi...

Страница 17: ...operation should be required only a few times in each heating season with very low quantities of water otherwise look for the leak and repair it 2 Draining We advise you against draining the system un...

Страница 18: ...18 Remeha P 420 06 04 06 300008441 001 C Spare parts P 420 To order a spare part quote the reference number next to the part required 10 02 06 UK 300004749 002 B Boiler body...

Страница 19: ...19 06 04 06 300008441 001 C Remeha P 420 Cladding...

Страница 20: ...20 Remeha P 420 06 04 06 300008441 001 C Insulating material for body Panel RC 1...

Страница 21: ...with opening 175 19 8229 0531 Plate for combustion chamber door with opening 190 19 8229 0533 Plate for combustion chamber door with opening 240 19 8339 0509 Plate for combustion chamber door with op...

Страница 22: ...8545 8003 Complete side panel left width 610 mm 112 8545 8005 Complete side panel left width 930 mm 113 8545 8007 Complete front side panel right 114 8545 8000 Complete side panel right width 610 mm...

Страница 23: ...23 06 04 06 300008441 001 C Remeha P 420...

Страница 24: ...ctions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior consent in writing Ours is a policy of continuous development We re...

Отзывы: