17
The supply cable of this appliance must not be
replaced by the user.
The electric power cable must never be under
mechanical tension and must be protected against
accidental crushing.
The use of any electric appliance requires the
respect of some basic rules:
-
Do not touch the appliance with wet or damp
hands or feet.
-
Do not use the appliance bare-footed or with
unsuitable clothing.
-
Do not pull the supply cable or the appliance
itself in order to disconnect the plug from the
electric supply. (For water cleaners rated at
less than 3 kW fitted with plug).
In case of damage or malfunction, switch off the
appliance (disconnecting it from the water main
and from the electricity main via the omnipolar
switch or by unplugging the plug in the case of
water cleaners rated at less than 3 kW)
Apply to one of our technical service cen-
tres.
Failure to observe the above warning frees
the manufacturer from all responsibility and
constitutes negligent use of the product.
STOPPING THE CLEANER
1)
After using with detergent, flush out the intake
circuit; place the detergent suction hose (fig. 12)
in a tank of clean water and let the pump run for
1 minute with the dosing tap turned fully on and
the lance in detergent delivery condition.
2)
Stop the water cleaner with the ON/OFF switch
in the “O” position (fig. 10A).
3)
Discharge the pressure from the H.P. hose by
pressing the trigger on the gun.
4)
Disconnect the water cleaner from the mains
electricity supply via the omnipolar switch or by
unplugging the plug from the socket.
5)
Turn off the water supply tap (fig. 8A).
If the water cleaner is left, even tempo-
rarily, turn it off by using the omnipolar
switch or by unplugging the plug from
the socket.
Water cleaners with the “Total Stop” device should
be considered as off when the omnipolar switch
is in the “O” position or the plug is unplugged
from the socket.
When the water cleaner is not used, close the
safety device on the handle (fig. 13).
Dry use of the water cleaner causes serious da-
mage to pump gaskets.
IMPORTANT!
To eliminate any impurities or air bubbles
from the water circuit we advise starting the
cleaner for the first time without the lance and
letting the water run out for a few seconds.
Impurities could block the nozzle and cause
malfunction (Fig. 11).
USING THE CLEANER
CONTROL PANEL
A
- On/off switch
B
- Detergent control tap (if available).
STARTING THE CLEANER
1)
Turn on the water supply tap (fig. 8A).
2)
Connect the water cleaner to the mains electri-
city supply via the omnipolar switch or by plugging
the plug into the socket.
3)
Start the water cleaner with the ON/OFF switch
in the “I” position (fig. 10A).
The high pressure water jet generates a reaction
force in the lance. Keep a firm grip on the lance
handle.
4)
Press the trigger on the gun and begin
washing.
In water cleaners with the “Total Stop” system, the
motor starts and stops when the lever on the lance
handle is actioned or released.
Do not block the handle lever in the delivery
position.
Содержание HDEm 662
Страница 1: ...HDEm 662 HDEm 962 D EN CZ LV E P DK N SF GR HU ET LT SLO PL RU...
Страница 3: ......
Страница 5: ...Fig 1 Fig 4 Fig 7 Fig 10 Fig 2 Fig 5 Fig 8 Fig 11 Fig 3 Fig 6 Fig 9 Fig 12 30 mA A B C A B C FIG 7...
Страница 85: ...84 i CE Fig 1 Fig 2 Fig 3 Fig 4 I IEC 60364 1 3 kW kW 1 72...
Страница 86: ...85 25 250 bar 360 3600 PSI IEC 60364 1 3 mm 3 kW Total stop O 6 7 12 5...
Страница 87: ...86 3 Kw 8 8 2 8 BAR 29 116 PSI 50 C 122 F 8C...
Страница 88: ...87 3 Kw 3 Kw 1 8 1 2 10 3 4 5 8 Total stop O 13 A B 1 8 2 3 10 simbolo 4 Total stop...
Страница 89: ...88 1 2 3 1 2 3 4 8 1 08 7 5 4 1 2 3 16 C...
Страница 90: ...89 1 2 6 3 4 5 6 7 8 18 18 50 500 1 18C 2 18 3 4 19 6 W40 20 1 50 500 50 50 200...
Страница 148: ...147...
Страница 149: ...148 7RWDO 6WRS o p...
Страница 150: ...149 c...
Страница 151: ...150 o 7RWDO 6WRS o p o p 7RWDO 6WRS...