9.10
Programming Emergency Operation
Emergency operation is programmed using the Emergency pane from the General tab for the selected
trunking system.
9.10.1
Emergency Alarm
Enabling emergency alarm will cause the radio to send the emergency alarm message once the
emergency has been activated (Press and hold emergency function key for approximately two seconds).
Supported options are 1) None, Normal and Silent. The retry counter setting is the number of times the
radio will repeat the alarm message to the infrastructure until it is acknowledged. Once the radio
receives an acknowledge from the system, the radio will indicate the emergency alarm has been
acknowledged.
9.10.2
Tone on Received Emergency Call
If enabled, the radio will indicate an audible tone upon receipt of radio traffic which includes an active
emergency signal. The radio will also display Emergency and the unit ID or alias of the radio initiating
the emergency.
9.10.3
Emergency Call
If enabled, when the emergency condition has been activated, the radio will send all voice traffic with
the emergency condition asserted. This will allow other radios and dispatch consoles to display a visual
indicator and generate an audible tone (if tone on receive emergency call is enabled).
9.10.4
Emergency Call Cancel
For infrastructure systems that permit the subscriber radio to cancel the emergency call select this
option. This option is not supported on Motorola systems.