![ReliOn SS2280 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/relion/ss2280/ss2280_user-manual_1436465024.webp)
Introduction
1230B0033901
1-7
The detailed LED information is shown below:
Table 1-5 LED Information
Type of LED
Color
Status
Front View LEDs
Blue
On: Normal operating state
Power LED
−
Off: System is in the off state
On: Critical Fault (Two or more fan
sensors fail)
Red
Blinking: Non-critical Fault (One fan
sensor fails)
Fan Fail LED
−
Off: Operation normal
On: Critical Fault (System needs to be
shut down and service)
Red
Blinking: Non-critical Fault (System
Errors)
System Health LED
−
Off: Operation normal
On: HDD present
Blue
Blinking: HDD data access
On: HDD fault
Red
Blinking: HDD rebuilding
HDD Tray LED
−
Off: No HDD present
Back View LEDs
Blue
On/Blinking: Chassis Identify
UID LED
−
Off: Disabled
On: Linking On
Green
Blinking: (At 1Hz rate) Access
NIC Link/Activity
LED
−
Off: No Link
Amber
On: Linking at 1Gbps speed
Green
On: Linking at 100Mbps speed
NIC Speed LED
−
Off: Linking at 10Mbps speed
On: Linking on
Green
Blinking: (At 1Hz rate ) Access
Link/Activity LED of
Management Port
−
Off: No link
Green
On: Linking at 100Mbps speed
Speed LED of
Management Port
−
Off: Linking at 10Mbps speed
On: Output ON and OK
AC Power LED
Green
Blinking:(At 1Hz) AC present/Only
5VSB on (PS off)
Содержание SS2280
Страница 1: ...2U Storage System User Manual SS2280 Jun 2007 Revision C P N 1230B0033901 ...
Страница 26: ...Motherboard Layout Screw Holes Processor System Memory System Configuration Jumper Chapter 2 Motherboard ...
Страница 68: ...Connectors and Pin 1 Locations Cable Connections Power Supply Power On Chapter 4 Cable Connections ...
Страница 82: ...Appendix China RoHS Regulations ...
Страница 83: ...Appendix 1230B0033901 I Appendix China RoHS Regulations Appendix Figure I China RoHS Regulations ...