FV Sensor

FIGURE 1.

The patented system protects your family by trapping 

the burning vapors within the water heater combustion 

chamber through the special flame-arrestor. The burning 

vapors literally “burn themselves out” without escaping 

back into the room. In the event of a flammable vapor 

incident, the FVIR System disables the water heater by 

shutting off the gas supply to the water heater’s burner and 

pilot, preventing re-ignition of any remaining flammable 

vapors in the area. This will not prevent a possible fire/

explosion if the igniter activates and flammable vapors 

have accumulated in the combustion chamber with the 

pilot light off. If you suspect a flammable vapor incident 

has occurred, do not use this appliance. Do not attempt to 

light this appliance, if you suspect flammable vapors have 

accumulated inside or outside the appliance. Immediately 

call a qualified technician to inspect the appliance. Water 

heaters subjected to a flammable vapors incident will 

show a discoloration on the flame-arrestor and require 

replacement of the entire water heater.

WARNING

Flammable Vapors

FLAMMABLES

         

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 
appliance. Storage of or use of gasoline or other 
flammable vapors or liquids in the vicinity of this or 
any other appliance can result in serious injury or 
death.

Read and follow water heater warnings and 
instructions

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Do not use or store flammable products such as gasoline, 

solvents, or adhesives in the same room or area near the 

water heater. If such flammables must be used, all gas 

burning appliances in the vicinity must be shut off and their 

pilot lights extinguished. Open the doors and windows for 

ventilation while flammable substances are in use. 

If flammable liquids or vapors have spilled or leaked in 

the area of the water heater, leave the area immediately 

and call the fire department from a neighbor’s home. Do 

not attempt to clean the spill until all ignition sources have 

been extinguished.

Fire or Explosion Hazard

WARNING

•  Read instruction manual before installing, using or 
  servicing water heater.

•  Improper use may result in fire or explosion.

•  Maintain required clearances to combustibles.

Keep combustibles such as boxes, magazines, clothes, etc. away 
from the water heater area. 

Site Location

                                                          

• 

Select a location near the center of the water piping 

system. The water heater must be installed indoors 

and in a vertical position on a level surface. DO NOT 

install in bathrooms, bedrooms, or any occupied room 

normally kept closed.

• 

Locate the water heater as close to the chimney or gas 

vent as practical. Consider the vent system piping and 

combustion air supply requirements when selecting the 

water heater location. The venting system must be able 

to run from the water heater to termination with minimal 

length and elbows. 

• 

Locate the water heater near the existing gas piping. 

If installing a new gas line, locate the water heater to 

minimize the pipe length and elbows. 

• 

The water heater should be located in an area not 

subject to freezing temperatures. Water heaters 

located in unconditioned spaces (i.e., attics, 

basements, etc.) may require insulation of the water 

piping and drain piping to protect against freezing. 

The drain and controls must be easily accessible for 

operation and service. Maintain proper clearances as 

specified on the rating plate.

• 

Do not locate the water heater near an air-moving 

device. The operation of air-moving devices such 

as exhaust fans, ventilation systems, clothes dryers, 

fireplaces, etc., can affect the proper operation of the 

water heater. Special attention must be given to condi-

tions these devices may create. Flow reversal of flue 

gases may cause an increase of carbon monoxide 

inside of the dwelling (Figure 1).

• 

If the water heater is located in an area that is 

subjected to lint and dirt, it may be necessary to 

periodically clean the base-ring filter and flame-

arrestor (see External Inspection & Cleaning of the 

Flame-arrestor). 

NOTE:  This water heater must be installed according to all 

local and state codes or, in the absence of local and state 

codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 

54)-current edition.

Содержание 616 series

Страница 1: ...ny electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call...

Страница 2: ...Installation 17 Important Information About this Water Heater 18 Operating Your Water Heater 19 21 Lighting Instructions 19 Checking the Draft 20 Burner Flames 20 Emergency Shutdown 20 Water Temperat...

Страница 3: ...t water heaters and have a thorough understanding of this instruction manual Service Agency A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing air sup...

Страница 4: ...oid all ignition sources if you smell Natural or LP gas Do not expose water heater control to excessive gas pressure Use only gas shown on rating plate Maintain required clearances to combustibles Kee...

Страница 5: ...n Valve U Pilot and Main Burner V Flue W Metal Drain Pan X Igniter Wire Y Base Ring Filter Z FV Sensor AA Transformer BB Flue Damper ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS TO VENT TERMINATIO...

Страница 6: ...instructions you should not proceed but have a qualified technician perform the installation of this water heater Massachusetts code requires this water heater to be installed in accordance with Mass...

Страница 7: ...to clean the spill until all ignition sources have been extinguished Fire or Explosion Hazard WARNING Read instruction manual before installing using or servicing water heater Improper use may result...

Страница 8: ...ctor or water shut off device used in conjunction with a piped metal drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in variou...

Страница 9: ...ural gas water heater to an L P gas supply Do not connect an L P gas water heater to a natural gas supply Failure to follow these instructions can result in death explosion or carbon monoxide poisonin...

Страница 10: ...in the occurrence of a leak in the system the gas will settle at floor level Basements crawl spaces closets and areas below ground level will serve as pockets for the accumulation of gas Before lighti...

Страница 11: ...y a qualified technician using the installation instructions Examples of a qualified technican include gas technicians authorized gas company personel and authorized service persons Failure to so do c...

Страница 12: ...typical examples of each method Louvers and Grilles In calculating free area for ventilation and combustion air supply openings consideration must be given to the blocking effect of protection louver...

Страница 13: ...re certified by CSA International this certification applies to the vent damper device only and does not mean they are certified for use on this water heater U L recognized fuel gas and carbon monoxid...

Страница 14: ...Before connecting a vent to a chimney make sure the chimney passageway is clear and free of obstructions The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces...

Страница 15: ...off valve in the cold water inlet line It should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 6 A temperatu...

Страница 16: ...se excessive restriction to water flow is not recommended Use only 95 5 tin antimony or other equivalent solder Any lead based solder must not be used Piping that has been treated with chromates boile...

Страница 17: ...h duct tape 7 Repeat steps 5 and 6 for the hot water outlet pipe 8 Add additional sections of pipe insulation as needed T P RELIEF VALVE T P RELIEF VALVE MANUAL RELIEF LEVER T P RELIEF VALVE INSULATIO...

Страница 18: ...es Questions Contact Residential Technical Assistance by referencing the phone number on the front of the Installation Instructions and Use Care Guide Installation Checklist Water Heater Location Wate...

Страница 19: ...ier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to turn the gas control knob Never use tools If the...

Страница 20: ...emperature range of 120 F 140 F 49 C 60 C is recommended by most dishwasher manufacturers The thermostat of this water heater has been factory set at the VAC Vacation position It is adjustable and mus...

Страница 21: ...erature set by the user Vacation Setting The Vacation Setting VAC sets the controller at approximately 70 F This setting is recommended when the water heater is not in use for a long period of time Th...

Страница 22: ...YL YL BN 24VAC V 24VAC BK 120VAC WH 120VAC GR BK 24VAC HOT WH 24VAC NEUTRAL BL RD BL RD YL YL BK 24VAC HOT WH 24VAC NEUTRAL YL 24VAC YL 24VAC TRANSFORMER YL 24 VAC GAS CONTROL VALVE THERMOSTAT FV SENS...

Страница 23: ...ce information at 1 800 365 4054 A temperature limit switch or ECO Energy Cut Off sensor located in the gas control valve thermostat is used to shut off the water heater if the water temperature excee...

Страница 24: ...ting Your Water Heater See the Repair Parts Illustration section for anode rod location TEFLON is a registered trademark of E I Du Pont De Nemours and Company Draining and Flushing It is recommended t...

Страница 25: ...ush down slightly to free the manifold and pilot tube 7 Carefully remove the manifold assembly from the burner compartment NOTE Be sure not to damage internal parts Replacement Parts IMPORTANT The fol...

Страница 26: ...lot before going to the next step FIRST BEND S OTHER FITTINGS NOT SHOWN FOR CLARITY PILOT TUBE SCREWS OLD PILOT IGNITER FLAME SENSOR ASSEMBLY FIGURE 30 7 Push the new pilot tube and igniter wire throu...

Страница 27: ...ssembly door is tightened visually inspect the door gasket between the manifold burner assembly door and the combustion chamber for spaces or gaps that would prevent a seal IMPORTANT Do not operate th...

Страница 28: ...26 NOTE L P Gas systems use reverse left hand threads on the manifold tube 6 Refer to Gas Piping section Figure 5 and disconnect the ground joint union in the gas piping Disconnect the remaining pipe...

Страница 29: ...roubleshooting Table section 2 See Pilot Light Troubleshooting Flowchart section 3 Seat connector firmly in socket 4 Bleed the air from the gas line 5 Check with gas utility company 6 Check with gas u...

Страница 30: ...at COMBUSTION ODORS 1 Insufficient secondary air 2 Flue clogged 3 Heater installed in a confined area 1 Provide ventilation to water heater Check flue way flue baffle and burner 2 Clean locate source...

Страница 31: ...wer switch on the gas control valve to the OFF position and unplug the power cord from the power outlet 1 Attempt to depress the TCO door switch button see figure 27 If the TCO door switch button depr...

Страница 32: ...e electrode flame sense rod replace the igniter pilot assembly Follow the directions on page 27 to re install the burner assembly into the combustion chamber Follow the instructions for lighting on pa...

Страница 33: ...alve Open Is Main Flame Sensed Is Demand for Heat Satisfied Pilot Main Valve De Energize Is Flame Sensed Damper Energizes and Closes Will not light 8 4 flash error code See Corrective Action Table on...

Страница 34: ...List Item No Parts Description 1 DRAFT HOOD 2 FLUE DAMPER 3 FLUE BAFFLE 4 HEAT TRAP COLD SOME MODELS 5 HEAT TRAP HOT SOME MODELS 6 COLD WATER DIP TUBE 7 ANODE ROD 8 TEMPERATURE PRESSURE RELIEF VALVE L...

Страница 35: ...assembly which contains the manifold tube gasket door pilot igniter flame sensor assembly manifold component block with retainer clip thermal switch and pilot tube Natural Gas Low Nox Item 14B Manifol...

Страница 36: ...36 NOTES...

Страница 37: ...37 NOTES...

Страница 38: ...38 NOTES...

Страница 39: ...ntaminated atmosphere used with factory approved anode s installed in its original installation location in the United States its territories or possessions and Canada sized in accordance with proper...

Страница 40: ...OF USE OF THE UNIT INCONVENIENCE LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER CONSEQUENTIAL DAMAGE THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS...

Отзывы: