4.1 Log Data
The chief function of the
DL-04
is the Log Data process.
The screen prompts the operator through the necessary steps, issuing
instructions as required. Once the operator initiates a job, each record is
saved automatically for future transfer and analysis.
Once logging has begun, the screen is updated every log interval with
the latest log information. This maintains a record of:
•
Tool Depth with units
•
Line Speed with units
•
Entry Time
•
Line Load with units
•
Entry Number (max. 113,825)
1. From the Main Menu, select Log
Data.
MAIN MENU
1 Log Data
2 Resume Logging
Select # more:
T
Operator is prompted for required
information starting with Well Name
Well Name:
F2
: Alpha
F4
: Quit
ENTR: Accept
2. Key in the Well name.
Example:
K14
If letters are used press
F2
to enter alpha mode
The screen will change slightly
Well Name:
F2
: Accept alpha
f
: Next position