background image

Reliable Scale Corporation

 

 

 

Model DL-04 DATA-LOGGER 

User Manual 

Page 24 of 38 

Rev. 1.70

 

5.3.1  Show Port Function 

The current port assignments can be seen by using the Show Port 
Function option in the Port Config Menu.  This can be a useful 
troubleshooting tool if device communications problems arise. 

 

1.  From the Port Config Menu, select 

Show Port Function

 

  PORT CONFIG MENU 

1 Show Port Function 

2 Set Port Function 

Select #      more:

S

 

 

 

 

 

 

 

2.  Screen shows first Port Functions. Use 

the 

UP

 and 

DOWN

 arrow keys to scroll 

through the list.

 

   PORT FUNCTIONS 

PC Port:           1 

Counter Port:      2 

F4

: Quit      more:

S

 

 

 

 

PORT FUNCTIONS 

Weight Port        3 

Printer Port       1  

F4

: Quit      more:

S

 

 

 

3.  To quit, press 

F4

.

 

 

 

Содержание Data-Logger DL-04

Страница 1: ...LOGGER WIRELINE DATA LOGGER USER MANUAL 1996 2008 Reliable Scale Corporation Reliable Scale Corporation 520 Moraine Road N E Calgary Alberta Canada Tel 1 800 419 1189 403 272 8784 Fax 403 273 9818 E...

Страница 2: ...4 3 Delete Data 11 4 4 View Job Information 13 4 5 Plot Chart 14 4 6 Print Data 16 5 Configuration 18 5 1 Set Date 19 5 2 Set Time 21 5 3 Configure Ports 23 5 3 1 Show Port Function 24 5 3 2 Set Port...

Страница 3: ...with the operator s normal activities The DL 04 monitors the truck s digital weight indicator depth meter and line speed meter as often as every 2 seconds and stores the information securely in memor...

Страница 4: ...phanumeric Keys operator keys in information Data Control Keys for Entering and Editing data RS 232 Ports 4 pin female military style connectors P N PT02A8 4S to connect devices to the DL 04 Example D...

Страница 5: ...ate time for operator verification with local time zones RELIABLE SCALE DL 04 DATA LOGGER 1999 03 29 14 09 23 F1 Continue 2 Press F1 to continue Screen shows the first two options available from the M...

Страница 6: ...le Scale Corporation Model DL 04 DATA LOGGER User Manual Page 6 of 38 Rev 1 70 5 When an process has been completed the DL 04 will return to the Main Menu MAIN MENU 1 Log Data 2 Resume Logging Select...

Страница 7: ...begun the screen is updated every log interval with the latest log information This maintains a record of Tool Depth with units Line Speed with units Entry Time Line Load with units Entry Number max 1...

Страница 8: ...pha F 4 Quit ENTR Accept 5 Input numbers normally 6 Well Number is next Follow the same procedure as for Well Name Well Number F 2 Alpha F 4 Quit ENTR Accept 7 Key in Well Number Example 45 Well Numbe...

Страница 9: ...Key in Job Operator Example 58 Job Operator 58 F 2 Alpha F 4 Quit ENTR Accept Log Interval is next Intervals from 2 seconds to 99 seconds between records are available Log Interval s Min 2s Max 99s F...

Страница 10: ...resumed If there are no jobs in memory this process cannot be used 1 From the Main Menu select Resume Logging MAIN MENU 1 Log Data 2 Resume Logging Select more T The operator is asked to confirm the...

Страница 11: ...r each day to make room for new ones and to eliminate confusion 1 From the Main Menu select Delete Data MAIN MENU 2 Resume Logging 3 Delete Data Select more T The operator is asked to confirm the dele...

Страница 12: ...Scale Corporation Model DL 04 DATA LOGGER User Manual Page 12 of 38 Rev 1 70 If a valid password has been entered the records are deleted and the status is displayed on the screen Deleting data Data...

Страница 13: ...e Main Menu select View Job Info MAIN MENU 3 Delete Data 4 View Job Info Select more T If there is more than one job in memory the user will be prompted for the job number VIEW JOBS Job to View 3 F 4...

Страница 14: ...stored permanently in memory and can only be removed by using the Delete Data option see section 4 3 on page 11 Data transfer can be done as many times as desired before deletion Note The DL 04 has be...

Страница 15: ...Reliable Scale Corporation Model DL 04 DATA LOGGER User Manual Page 15 of 38 Rev 1 70 4 To quit printing press F4...

Страница 16: ...for this procedure see your terminal program manual for details Transferring jobs to computer does not remove them from the DL 04 s memory Records are stored permanently in memory and can only be remo...

Страница 17: ...Reliable Scale Corporation Model DL 04 DATA LOGGER User Manual Page 17 of 38 Rev 1 70 4 To quit printing press F4...

Страница 18: ...set from the Configuration Menu 1 From the Main Menu select Configuration MAIN MENU 6 Pint Data 7 Configuration Select more S 2 Screen shows first two items of the Configuration Menu Use the UP and DO...

Страница 19: ...te log information If the date needs to be changed it is done using the Set Date process from the Configuration Menu 1 From the Configuration Menu select Set Date CONFUGIRATION MENU 1 Set Date 2 Set T...

Страница 20: ...iable Scale Corporation Model DL 04 DATA LOGGER User Manual Page 20 of 38 Rev 1 70 The new date is displayed before returning to the Configuration Menu SET DATE Date set to 1999 02 12 5 To quit press...

Страница 21: ...e log information If the time needs to be changed it is done using the Set Time process from the Configuration Menu 1 From the Configuration Menu select Set Time CONFUGIRATION MENU 1 Set Date 2 Set Ti...

Страница 22: ...liable Scale Corporation Model DL 04 DATA LOGGER User Manual Page 22 of 38 Rev 1 70 The new time is displayed before returning to the Configuration Menu SET TIME Time set to 14 25 50 5 To quit press F...

Страница 23: ...3 Weight Indicator 1 From the Configuration Menu select Configure Ports CONFIGURATION MENU 2 Set Time 3 Configure Ports Select more S 2 Screen shows first items of the Port Config Menu Use the UP and...

Страница 24: ...a useful troubleshooting tool if device communications problems arise 1 From the Port Config Menu select Show Port Function PORT CONFIG MENU 1 Show Port Function 2 Set Port Function Select more S 2 S...

Страница 25: ...is recommended that the default port assignments be used 1 From the Port Config Menu select Set Port Function PORT CONFIG MENU 1 Show Port Function 2 Set Port Function Select more S 2 Key in the port...

Страница 26: ...is important that this setting is correct for proper device interfacing Supported Baud Rates 1200 2400 4800 9600 19 200 38 400 115 200 1 From the Port Config Menu select Set Port Speed PORT CONFIG MEN...

Страница 27: ...Reliable Scale Corporation Model DL 04 DATA LOGGER User Manual Page 27 of 38 Rev 1 70 SET PORT FUNCTION Port 1 Speed 9600 baud 4 To quit press F4...

Страница 28: ...the device connected to it It is important that these settings are correct for proper device interfacing Supported Word Lengths 7 8 1 From the Port Config Menu select Show Port Function PORT CONFIG ME...

Страница 29: ...orporation Model DL 04 DATA LOGGER User Manual Page 29 of 38 Rev 1 70 4 Choose the parity setting Example 5 None Select Parity 1 Even 2 Odd 3 Mark 4 Space 5 None SET PORT FORMAT Port 1 Format 8 N 1 5...

Страница 30: ...used when connected to the measurement devices as they can be damaged This can be a useful troubleshooting tool if device communications problems arise and should only by used by trained personnel A t...

Страница 31: ...ts to used for logging 1 From the Configuration Menu select Set Depth Units Configuration MENU 3 Configure Ports 4 Set Depth Units Select more T 2 Key in the depth units Example 1 meters SET UNITS Sel...

Страница 32: ...length of time is determined by the Plot Delay setting and is measured in milliseconds 1 From the Configuration Menu select Plot Delay CONFIGURATION MENU 5 Plot Delay 6 Set Password Select more S 2 T...

Страница 33: ...assword Configuration MENU 3 Configure Ports 4 Set Password Select more T 2 Key in the old password CHANGE PASSWORD Old Password F 4 Quit When the password is entered s are displayed for security 4 Ke...

Страница 34: ...Reliable Scale Corporation Model DL 04 DATA LOGGER User Manual Page 34 of 38 Rev 1 70 6 To quit press F4...

Страница 35: ...r is properly plugged in and is supplying 12VDC Pin A of the power connector is positive pin B is negative 2 When transferring data to the computer nothing happens or else the data looks like garbage...

Страница 36: ...0 lb 0 5818 lb 100 Depth 0 m 0 38 54 m 100 0 25 50 75 100 08 23 35 08 23 37 08 23 39 08 23 41 08 23 43 08 23 45 08 23 47 08 23 49 08 23 51 08 23 53 08 23 55 08 23 57 08 23 59 08 24 01 08 24 03 08 24 0...

Страница 37: ...76kg 206 51m 65m m 7 7 15 28 58 5376kg 208 77m 61m m 8 8 15 29 00 5376kg 210 12m 65m m 9 9 15 29 02 5376kg 212 24m 54m m 10 10 15 29 04 5376kg 214 08m 50m m 11 11 15 29 06 5376kg 216 15m 48m m 12 12 1...

Страница 38: ...ELIABLE SCALE CORPORATION within the warranty period This warranty does not extend to any consequential damage of other equipment loss of use commercial or economic loss or inconvenience prior to or d...

Отзывы: