4.5 Plot Chart
Data saved in the
DL-04
can be transferred to a printer or computer in
the form of a chart (Line Pull and Depth vs. Time). Connect the
DL-04
to the printer or computer with the proper cables & hardware. Be sure
the printer/computer is ready to receive the data. The default serial port
configuration for the
DL-04
is 9600 baud, 8 data bits, no parity, 1 stop
bit.
Plotting a job does not remove it from the
DL-04
’s memory. Records
are stored permanently in memory and can only be removed by using
the Delete Data option (see section 4.3, on page 11). Data transfer can
be done as many times as desired before deletion.
Note: The DL-04 has been configured for use with an Epson FX-880
printer with an RS-232 serial interface. Other compatible printers should
function, but proper operation is not guaranteed.
1. From the Main Menu, select Plot Chart.
MAIN MENU
5 Plot Chart
6 Print Data
Select # more:
T
If there is more than one job in memory,
the user will be prompted for the job
number.
PLOT CHART
Job to Print? (3)
F4
: Quit
2. Enter job number to plot.
3. During data transfer, the number of the
entry currently being plotted is
displayed.
PLOT CHART
Plotting record: 457
F4
: Quit