THERMOJET
®
H-2000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740121
Rev
15
Date
June 2020
Page
50
of
102
Oil Mist Eliminator Maintenance
The ThermoJet Oil Purifier must be shut down before performing maintenance on the oil mist
eliminator. The oil mist eliminator is located on the left side of the unit. Maintenance involves
removing and cleaning the oil filter housing and replacing the filter element.
First shut down the ThermoJet. See the section titled
Shut Down Procedures
on how to turn the
ThermoJet Oil Purifier OFF.
Close and tag the nearest oil block valve to the ThermoJet oil inlet and outlet connection.
To remove the filter housing first remove the drain tube from the bottom of the filter housing. Next
firmly grasp the filter housing with both hands and lift upward and turn to the left (Clock wise). The
filter housing can then be lowered away from the filter mounting head. To remove the filter
element grasp and pull down. The filter element will slide off of the filter mounting nipple.
Inspect the interior of the filter housing and wipe clean as necessary. Check the drain tube to
insure that it is clear and unobstructed. Install a new filter element by sliding onto the mounting
nipple. Replace the filter housing by sliding it over the newly installed element, then pushing it
upward against the bottom of the filter mounting head and turning to the right (C-Clock wise).
Reinstall the drain tube to the bottom at the bottom of the oil mist eliminator.
Locate the oil mist
eliminator
Drain tube
Filter housing
Filter element
Filter mounting head