Monitoring Normal Operation
Although the ThermoJet H2000E may be used to clean lubricants in batch operations, it is most
commonly installed to clean oil in a single dedicated reservoir. The H2000E is recommended for
use on oil reservoirs with a capacity of up to 2500 gallons (9500 liters). Initial and sustained oil
cleanliness is maintained by continuous operation, with initial results being achieved in 8-12
“passes” after starting. The number of initial passes necessary to clean the oil in a reservoir is
contingent upon the contamination level present when the system is put into service and any
active ingression rate into the serviced reservoir. The time necessary for the H2000E to complete
a single pass can be determined by;
𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅
𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝑅𝑅𝐶𝐶𝐶𝐶
(
𝑔𝑔𝐶𝐶𝑔𝑔𝑔𝑔𝑅𝑅𝑔𝑔𝑅𝑅
)
3.2
=
𝑚𝑚𝑅𝑅𝑔𝑔𝑚𝑚𝐶𝐶𝑅𝑅𝑅𝑅
/
𝐶𝐶𝐶𝐶𝑅𝑅𝑅𝑅
Oil samples can be collected from user installed sample points or from the oil sample valve
located in the inlet pump discharge line of the ThermoJet.
NOTICE:
Verification of oil cleanliness should be verified
thorough a suitable laboratory analysis.
Use Oil Sample Valve to collect
samples.