Open the Controller Enclosure and interchange any two of the three incoming power supply leads at the
circuit breaker. Ensure all cable terminations are secure before closing and securing the enclosure door
with all bolts.
Turn the Main Disconnect handle to the ON position, and again use the ON-OFF Selector Switch to jog the
electric motor and verify proper motor rotation. Once the motor rotation is correct leave the Selector Switch
in the ON position and allow the motor to run.
Ensure that all sources of electrical power are
disconnected before opening the controller.
Failure to do so may result in serious injury or
even death
.
To avoid risk of explosion hazard, the Controller
Enclosure cover must be securely closed with the
supplied fasteners.
WARNING
Main Disconnect in ON Position
Use ON-OFF Selector Switch to
jog Motor