![RelaDyne THERMOJET G3700E Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/reladyne/thermojet-g3700e-series/thermojet-g3700e-series_installation-and-operating-manual_1435626081.webp)
THERMOJET
®
G-3700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740151
Rev
03
Date
June 2020
Page
81
of
111
Types of Product Misapplication and Misuse Not Covered By Warranty or Guarantees
1.
Prolonged operation with air bubbles in the sight glass which causes pump cavitation
and/or relief valve chatter.
2.
Excessive water ingression beyond the system capability at maximum operating
temperature.
3.
Operating with inadequate oil flow caused by:
A.
Suction lines too small.
B.
Elevated sections of suction piping.
C.
Suction line restrictions.
D.
Excessively high viscosity.
E.
Excessive suction lift.
4.
Excessive solids contamination with no pre-filter.
5.
Presence of contaminants which are not within the scope of removal for air stripping
technology, for example heavy hydrocarbons, ethylene glycol, carbon black or
attempting to purify motor oils.
6.
Presence of contaminants which attack Viton seals.
7.
High differential pressure on oil filter.
8.
Operating without oil filter element or inlet Y-strainer element.
9.
Operating with inlet Y-strainer plugged.
10. Incoming oil temperature too cold for heater capacity (except for small reservoir
volumes).
11. Operating either above or below recommended operating pressures.
12. Operating with either inadequate or excessive nitrogen supply to the jet mixer.
13. Discharging oil into reservoir below the oil level.
14. Operating on under-voltage, over-voltage or wrong voltage.
15. Inadequate power supply, i.e. amperage rating of breaker or fuses under-sized for load
required.
16. Vent line piping not extending fifteen (15) feet above the
ThermoJet
.
17. Connection to pressurized reservoir without inlet pressure reducing valve or discharge
boosting means.
NOTICE:
If this is a temporary condition, free water may be drained manually from the
reservoir while a permanent solution is implemented. If it is constant condition,
request from customer service on the feasibility of installing an automatic water
drain valve.