Safety Measures to be taken during
Operation

The applicator must only be used by trained, instructed and authorized persons. These persons must have read the operating

instructions and be able to work accordingly. Before using the applicator, check it for visible damage and make sure that it is only

used when in proper and safe condition. Notify detected defects to the appropriate person immediately.

Safety Instructions for the Operation of the Hot­Melt Applicator

Only fill the tank up to 1.5 cm under the upper rim.

Never exceed the operating temperature of the hot melt.

This temperature is indicated in the technical

specification of the glue. Overheating may lead to

decomposition which may affect the health of the user as

well as the operability of the applicator.

Once the glue applicator has warmed up, nozzle and

lid are very hot.

Do not start working before fitting a nozzle first.

Only replace nozzle when applicator is warm.

Unplug the connecting cable before replacing a

nozzle. Warning: risk of burns! When a nozzle is

replaced, liquid glue might leak out.

Never bring the hot nozzle into contact with the cable.

Never direct the glue jet towards people.

Wear protective gloves and safety

goggles whenever you work with the

applicator.

Avoid accidents by stumbling – Lay all

cables, hoses and conducts so that they

will not cause any risk of stumbling. For

this, install cable ducts and bridges.

When your skin got into contact with hot

glue, cool it with cold water immediately.

Do not try to remove the hot­melt from the

skin first. If necessary, consult a doctor.

When hot adhesive got into your eyes,

immediately cool them under running

water for about 15 minutes and consult

your doctor at once.

Always deposit the glue applicator on the wire stand or

the respective plate destined for this purpose.

Do not lay the applicator on its side.

Never hold nozzle top upward. Otherwise hot­melt may

reach the lid. This causes the venting mechanism to get

clogged or also lets hot­melt leak out of the applicator

when the lid is opened.

Do not carry out overhead work.

Stop using the equipment, if the casing is damaged

due to shock, breakage or heavy wear.

Do not feed solvents or paraffin. Risk of explosion!

Содержание TR 50.4 25

Страница 1: ...0 4 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80 LCD Product Manual for Pneumatic Reka Glue Guns Translation from German to English www pakarte com TR 50 4 25 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80...

Страница 2: ...rouble Shooting 10 Environmental Protection 11 Additional Information 11 EU Declaration of Conformity 12 Spare Parts Technical Specifications Accessories TR 50 4 14 TR 55 LCD HT 16 TR 60 LCD HT 18 TR...

Страница 3: ...Leopoldshafen October 1st 2012 The applicator works with hot glue which is dispensed by a pneumatic conveying system Therefore this glue applicator should only be used by qualified persons who have be...

Страница 4: ...Available This operating manual shall always be kept at the place of operation of the applicator Be sure that all persons handling the applicator can consult the instructions at any time In addition t...

Страница 5: ...risk of burns When a nozzle is replaced liquid glue might leak out Never bring the hot nozzle into contact with the cable Never direct the glue jet towards people Wear protective gloves and safety go...

Страница 6: ...x 1 5 cm below upper rim Stop using the equipment if the casing is damaged due to shock breakage or heavy wear Is compressed air supplied to the glue applicator Is the applicator connected to a compre...

Страница 7: ...ancer Suspender If the glue applicator is fixed to a balancer suspender it is recommended to use the suspension 10436 Thereby it is avoided that by a wrong positioning glue gets into the vent valve Th...

Страница 8: ...ely in the cartridge Wear protective gloves and safety goggles whenever you work with the applicator When the applicator has warmed up there is a risk of burns If when changing the cartridge another t...

Страница 9: ...t glues Please check whether the complete spray head drawing Detail Front is fitted to the applicator if this is not the case attach it The spray cap 3088 must be screwed on slightly by hand never use...

Страница 10: ...and can be used for glueing again The working temperature of the respective glue may be taken from the technical datasheet which can be procured from the producer of the glue This temperature must not...

Страница 11: ...rom getting into the sound absorber when the applicator is ready for operation by depositing the glue applicator on a level plane using its wire bracket depositing the glue applicator on the stand 277...

Страница 12: ...hooting List of possible fault indications and assistance in trouble shooting In case of damage send the glue applicator to Reka indicating type and serial no of your applicator Self made repairs void...

Страница 13: ...cking material used by Reka Klebetechnik can be recycled completely Please take instructions for the disposal of hot melt glues and hot melt cartridges from the respective safety specifications Additi...

Страница 14: ...C from 20 09 2009 2004 108 EC until 28 12 2009 89 336 EEC from 29 12 2009 2006 42 EC 2002 95 EC The following standards have been applied IEC CISPR14 IEC 60335 IEC 60204 IEC 61000 This declaration of...

Страница 15: ...1 3 TR 50 4 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80 LCD Spare Parts Technical Specifications Accessories...

Страница 16: ...1 4 Spare Parts TR 50 4...

Страница 17: ...perating temperature 20 200 C Consistency of temperature 5 C Temperature indication analog Heat up time approx 3 10 min Gross Tank Capacity 250 ml Conveying system Air pressure Operating pressure 0 5...

Страница 18: ...1 6 Spare Parts TR 55 LCD HT...

Страница 19: ...Temperature limitation Temperature monitor Operating temperature 50 210 C 50 210 C 50 250 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross T...

Страница 20: ...1 8 Spare Parts TR 60 LCD HT...

Страница 21: ...on Temperature monitor Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross Tank Capacity 250 ml Conveying...

Страница 22: ...20 Spare Parts TR 700...

Страница 23: ...perating temperature 120 C Consistency of temperature 5 C Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying system Air pressure Operating pressure 0 5 6 bar Length of electric cord 8 5...

Страница 24: ...22 Spare Parts TR 70 LCD HT...

Страница 25: ...ion Temperature monitor Temperature indication digital Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying...

Страница 26: ...24 Spare Parts TR 80 LCD HT...

Страница 27: ...or Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying system Air pressure...

Страница 28: ...nsstra e 6 DE 76344 Eggenstein Telephone 49 721 970 780 Telefax 49 721 705 069 E Mail sale reka klebetechnik de Internet http www reka klebetechnik de www pakarte com TR 50 4 25 TR 55 LCD TR 60 LCD TR...