background image

8

20 min.

Cleaner

Cle

an

er

Cle

an

er

Cleaning and Maintenance

Proceed as follows:

Remove the PUR cartridge from the

applicator.

Unscrew the nozzle adapter from

the warm glue cartridge.

Use a pointed tool to open the outlet of

the PUR­cleaner cartridge.

Screw the nozzle adapter on the

screw thread of the cleaner cartridge.

Insert the cleaner cartridge in the

applicator. Please ask the glue

producer for the cleaning agent

suited for the glue used by you.

Allow about 20 minutes for the

applicator to warm up the cleaner.

Flush the nozzle adapter with

cleaner until you see cleaning

agent come out steadily.

Remove the cleaner cartridge from the applicator and

unscrew the nozzle adapter and nozzle from the cleaner

cartridge while it is still warm.

Caution: Hot cleaning agent may flow out!

Allow the cleaner cartridge to cool and keep it for further

use.

Never fill soiled glue into the melting tank. If you observe

all advices given in the operating manual, the glue

applicator does normally not need cleaning. The

nonreactive glue contained in the applicator will remelt

and can be used for glueing again.

The working temperature of the respective glue may be

taken from the technical datasheet which can be

procured from the producer of the glue. This temperature

must not be exceeded, otherwise the glue may coke in

the glue applicator. Hot­melts on a polyamide basis are

particularly sensitive. If the glue has coked, the applicator

should be cleaned.

Never clean the applicator with solvent, benzine,

benzene, toluene, acetone, turpentine, etc. risk of

explosion!

When reactive PUR hot­melt glues are used, the adapter

and the nozzles must be flushed thoroughly. For this, use

a special cleaning agent in 310ml cartridges. Please ask

your glue supplier for the cleaning agent suited for the

hot­melt used by you.

If the applicator is used very often, we recommend to

have it maintained regularly. For this, fix a date with our

service department.

Cleaning the Nozzle/Nozzle
Adapter after having
applied PUR Hot­Melt Cartridges
(TR 700 / 70 / 80)

Warning: risk of burns!

For your own safety you are advised to

wear protective gloves and safety goggles

when replacing nozzles.

When the applicator will not be used for a longer time,

we recommend that you clean the nozzle/the adapter

because reactive PUR hot­melts may harden within a

short time and cannot melt any more.

Содержание TR 50.4 25

Страница 1: ...0 4 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80 LCD Product Manual for Pneumatic Reka Glue Guns Translation from German to English www pakarte com TR 50 4 25 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80...

Страница 2: ...rouble Shooting 10 Environmental Protection 11 Additional Information 11 EU Declaration of Conformity 12 Spare Parts Technical Specifications Accessories TR 50 4 14 TR 55 LCD HT 16 TR 60 LCD HT 18 TR...

Страница 3: ...Leopoldshafen October 1st 2012 The applicator works with hot glue which is dispensed by a pneumatic conveying system Therefore this glue applicator should only be used by qualified persons who have be...

Страница 4: ...Available This operating manual shall always be kept at the place of operation of the applicator Be sure that all persons handling the applicator can consult the instructions at any time In addition t...

Страница 5: ...risk of burns When a nozzle is replaced liquid glue might leak out Never bring the hot nozzle into contact with the cable Never direct the glue jet towards people Wear protective gloves and safety go...

Страница 6: ...x 1 5 cm below upper rim Stop using the equipment if the casing is damaged due to shock breakage or heavy wear Is compressed air supplied to the glue applicator Is the applicator connected to a compre...

Страница 7: ...ancer Suspender If the glue applicator is fixed to a balancer suspender it is recommended to use the suspension 10436 Thereby it is avoided that by a wrong positioning glue gets into the vent valve Th...

Страница 8: ...ely in the cartridge Wear protective gloves and safety goggles whenever you work with the applicator When the applicator has warmed up there is a risk of burns If when changing the cartridge another t...

Страница 9: ...t glues Please check whether the complete spray head drawing Detail Front is fitted to the applicator if this is not the case attach it The spray cap 3088 must be screwed on slightly by hand never use...

Страница 10: ...and can be used for glueing again The working temperature of the respective glue may be taken from the technical datasheet which can be procured from the producer of the glue This temperature must not...

Страница 11: ...rom getting into the sound absorber when the applicator is ready for operation by depositing the glue applicator on a level plane using its wire bracket depositing the glue applicator on the stand 277...

Страница 12: ...hooting List of possible fault indications and assistance in trouble shooting In case of damage send the glue applicator to Reka indicating type and serial no of your applicator Self made repairs void...

Страница 13: ...cking material used by Reka Klebetechnik can be recycled completely Please take instructions for the disposal of hot melt glues and hot melt cartridges from the respective safety specifications Additi...

Страница 14: ...C from 20 09 2009 2004 108 EC until 28 12 2009 89 336 EEC from 29 12 2009 2006 42 EC 2002 95 EC The following standards have been applied IEC CISPR14 IEC 60335 IEC 60204 IEC 61000 This declaration of...

Страница 15: ...1 3 TR 50 4 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80 LCD Spare Parts Technical Specifications Accessories...

Страница 16: ...1 4 Spare Parts TR 50 4...

Страница 17: ...perating temperature 20 200 C Consistency of temperature 5 C Temperature indication analog Heat up time approx 3 10 min Gross Tank Capacity 250 ml Conveying system Air pressure Operating pressure 0 5...

Страница 18: ...1 6 Spare Parts TR 55 LCD HT...

Страница 19: ...Temperature limitation Temperature monitor Operating temperature 50 210 C 50 210 C 50 250 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross T...

Страница 20: ...1 8 Spare Parts TR 60 LCD HT...

Страница 21: ...on Temperature monitor Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross Tank Capacity 250 ml Conveying...

Страница 22: ...20 Spare Parts TR 700...

Страница 23: ...perating temperature 120 C Consistency of temperature 5 C Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying system Air pressure Operating pressure 0 5 6 bar Length of electric cord 8 5...

Страница 24: ...22 Spare Parts TR 70 LCD HT...

Страница 25: ...ion Temperature monitor Temperature indication digital Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying...

Страница 26: ...24 Spare Parts TR 80 LCD HT...

Страница 27: ...or Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying system Air pressure...

Страница 28: ...nsstra e 6 DE 76344 Eggenstein Telephone 49 721 970 780 Telefax 49 721 705 069 E Mail sale reka klebetechnik de Internet http www reka klebetechnik de www pakarte com TR 50 4 25 TR 55 LCD TR 60 LCD TR...

Отзывы: