![Reisinger s4000 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/reisinger/s4000/s4000_operating-manual_1435292005.webp)
Use the
<E>
key to acknowledge the selected para-
meter.
(Use the
<P>
key to abort the process)
>Display of the current parameter value
<
Use the
<+>
or
<->
key to change the desired value.
Use the
<E>
key to accept the preset parameter
value (here 12s).
>Display after pressing
<
E> key
<
2.9.5 Program selector
The following modes are available:
1.
Permanently open
2.
Closing time [ ↑ ]
3.
Winter mode [☼]
4.
Electrical lock [ ]
5.
Winter mode and closing time [☼↑]
6.
Manual mode
Example: PS mode >Closing time<
>Standard display,
PS
inactive
<
Parameter 61 = select 1.
>Display
PS mode
<
Use the
<+>
or
<->
key to select the desired mode
(here: Closing time [ ↑ ]). Use the
<E>
key to accept
this mode.
>Display
PS mode
active (blue LED) (Closing time)
<
2.9.6 Technical data
Voltage Supply : 100 VAC – 240 VAC
50Hz – 60Hz
Protection class (IP 00)
Suitable only in dry locations
Power supply for external equipment:
24 V DC / max. 1 A total input current
Power consumption: max. 210 W
Power consumption stand-by mode min.: 3 W
Ambient temperature: -15°C to 50°C
Humidity: max. 85% non-condensing
Average power consumption: 4 W/h
Max. speed of each door wing: 0,50 m/s
Installation dimensions: ( LxHxD) var. / 120 / 52 mm
Door weights:
Standard
up to 150 kg
Heavy (SK)
up to 250 kg
Load (SL)
up to 400 kg
V
EN
– 5 –
Содержание s4000
Страница 1: ...Operating Manual Sliding Door Drive Engine V EN ...
Страница 16: ...11 0 Terminal connection diagrams 11 1 Wiring diagram maximum total cable length 10m 16 ...
Страница 17: ...11 2 Terminal assignment V EN 17 ...
Страница 18: ...12 0 Dimensions 12 1 Sectional drawing one wing drive 18 ...
Страница 19: ...12 2 Sectional drawing telescopic and two wing drive V EN 19 ...