Parameter 22 :
Travelling speed in CLOSE direction. The parameter value should be between 100 mm/s and 200 mm/s.
In case of any change in speed, a new teach-in run must be carried out!
Parameter 23 :
Travelling speed to the OPEN/CLOSE end positions. The parameter value should be between 10 mm/s
and 30 mm/s.
In case of any change in speed, a new teach-in run must be carried out!
Parameter 24 :
Travelling speed during teach-in run. The parameter value should be between 30 mm/s and 40 mm/s.
In
case of any change in speed, a new teach-in run must be carried out!
Parameter 31:
Reversing sensitivity of the driving unit in OPEN direction when running into an obstacle. The works set-
ting of the parameter value is 700. It should only be modified
with care
! Smaller values signify a higher
sensitivity, greater values signify a lower sensitivity. In case of very small values, there is the risk of the
door not properly closing any longer – in case of very great values there is an
increased risk of injury
.
Parameter 32:
Reversing sensitivity of the driving unit in CLOSE direction when running into an obstacle. The works set-
ting of the parameter value is 500. It should only be modified
with care
! Smaller values signify a higher
sensitivity, greater values signify a lower sensitivity. In case of very small values, there is the risk of the
door not closing properly any longer – in case of very great values, there is an
increased risk of injury
.
Parameter 33:
The acceleration slope ensures a smooth starting of the door without any jerks. The works setting of the
parameter value is 500. It should only be modified
with care
! Smaller values signify a steeper slope, i.e.
the door is accelerated faster, greater values signify a more gentle slope, i.e. the door is accelerated less
fast.
Attention
! This parameter affects the service life of the driving mechanism on a long-term basis.
Very small values may reduce the service life of the driving mechanism.
In case of any change in the
acceleration slope, a new teach-in run must be carried out!
Parameter 34:
The braking slope OPEN ensures a fast slowing-down of the door in OPEN direction without any jerks.
The works setting of the parameter value is 400. It should only be modified
with care
! Smaller values
signify a steeper slope, i.e. the door is slowed down faster, greater values signify a more gentle slope,
i.e. the door is slowed down less fast.
Attention
! This parameter affects the service life of the driving
mechanism on a long-term basis. Very small values may reduce the service life of the driving mechan-
ism.
In case of any change in the braking slope, a new teach-in run must be carried out!
Parameter 35:
The braking slope CLOSE ensures a fast slowing-down of the door in CLOSE direction without any jerks.
The works setting of the parameter value is 1000. It should only be modified
with care
! Smaller values
signify a steeper slope, i.e. the door is slowed down faster, greater values signify a more gentle slope,
i.e. the door is slowed down less fast.
Attention
! This parameter affects the service life of the driving
mechanism on a long-term basis. Very small values may reduce the service life of the driving mechan-
ism.
In case of any change in the braking slope, a new teach-in run must be carried out!
Parameter 36 :
Number of reversions in case of obstacle on travel path
Parameter 37 :
Permanent partial-open
0 – disabled
1 – Function FullOpen
2 - converts to Permanent partial-open [29,30].
Define the opening width with
parameter 15
.
Parameter 38:
The speed-up slope CLOSE ensures a smooth and jerkless door run-up.
The parameter value is by default set to 300 and should only if at all be adjusted very carefully!
Smaller values translate to a steeper ramp, this means the door accelerates slower, higher values trans-
late to a lower ramp, this means the door accelerates faster.
Attention!
This parameter affects the ser-
vice life of the driving mechanism on a long-term basis. Very small values may reduce the service life of
the driving mechanism.
In case of any change in the braking slope, a new teach-in run must be car-
ried out!
Parameter 40:
Language option for terminal and RS232 edition:
1 – German
2 – English
Parameter 41:
Actual date
Parameter 42:
Actual time
Parameter 43:
Summertime
Parameter 50:
Start teach-in run
V
EN
– 11 –
Содержание s4000
Страница 1: ...Operating Manual Sliding Door Drive Engine V EN ...
Страница 16: ...11 0 Terminal connection diagrams 11 1 Wiring diagram maximum total cable length 10m 16 ...
Страница 17: ...11 2 Terminal assignment V EN 17 ...
Страница 18: ...12 0 Dimensions 12 1 Sectional drawing one wing drive 18 ...
Страница 19: ...12 2 Sectional drawing telescopic and two wing drive V EN 19 ...