Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
ADMIN SET POWER x ON
ADMIN SET POWER x OFF
*ADMIN SET POWER x ON
*ADMIN SET POWER x OFF
With these command various power saving measures can be set, differentiated according to voltage
source and voltage limits. See also
ADMIN SET LEVEL
.
For x, one of the following values can be used, which can be enabled with
ADMIN SET POWER x ON
or disabled with
ADMIN SET POWER x OFF
.
15 = DISABLE_OUTPUT_USB:
Disables all outputs (except fan), when the station is run in USB node
14 = DISABLE_FAN_USB:
Disables the fan, when the station is run in USB mode
13 = Reserved
12 = Reserved
11 = SHUTDOWN_HOURLY_ACCU: [priority 2]
Switches off the station in standard and in battery mode, powers up 5 minutes before the full
hour, and turns off 10 minutes later.
Caution!
Data is not logged in the meantime!
A combined operation with value 10 is also possible:
In the diagram illustrated, the storage interval is orange,
and the operating times of the station are shown in green.
10 = SHUTDOWN_LOGGING_ACCU: [Priority 2]
If the station is switched off in standard and in battery mode, it will boot up 30 seconds
before the next time the data is logged, then save and then switch off immediately.
9 = Reserved
8 = SLOWDOWN_RATE_ACCU
Outputs data in RS232 standard and battery mode only every 10 seconds.
This is maintained until the voltage is> = 7V [ADMIN SET LEVEL 2], or comes from USB.
7 = Reserved
6 = Reserved
5 = DISABLE_OUTPUT_ACCU:
Turns off all outputs (except fans) when the station is on battery power,
(Voltage < 7V [ADMIN SET LEVEL 2])
4 = DISABLE_FAN_ACCU:
Turns off the fan when the station is on battery power
(Voltage < 7V [ADMIN SET LEVEL 2])
3 = Reserved
2 = Reserved
1 = SHUTDOWN_STATION_MIN: [Priority 1]
Switches the station off in standard and battery mode when the voltage drops below the
minimum (Voltage < 3V [ADMIN SET LEVEL 1]).