Maintenance & Care 

WARNINGS! 

 

Always unplug unit before attempting to service. 

 

Release pressure before disconnecting spray gun and spray wand. 

 

Disconnect or unplug unit when not in use. 

 

Never immerse pump. 

 

Must be cleaned after every use: 

 

After spraying, remove the suction hose from the container.  Insert the wand tip into the 
container and squeeze the spray gun trigger.  Allow the unit to expel the unused material
 back into the container.  The wand and spray tip are left attached for this process to      
provide a back pressure that  will help expel 90% of the unused material out of the unit. 

 

Remove unit from the spraying solution container, and circulate either soapand water,    
diesel or other recommended cleaning solution through the unit until it comes out clean  
and clear.  NEVER USE XYLENE. 

 

Drain all liquid from the pump.  Do NOT allow liquid to freeze in the pump.  Failure to do 
so will result in damage to internal components of the pump. 

 
 

Trouble−shooting 

 

Fault 

Action 

Check the circuit breaker 

Check for proper voltage (+/−10%) & good electrical 

connections 

Check pressure switch for proper operation 

Check motor for an open or grounded circuit 

Pump will not start 

Check for a locked drive assembly 

Check for loose screws at the switch or pump head 

Switch diaphragm may be torn or pinched 

Leaks from pump head or switch 

Check pump diaphragm for tears or holes 