CUSTOMER SERVICE CENTRE 1300 780 250
Check for loose upper housing or drive screws
Noisy or rough operation
Is the surface that the pump is sitting on magnifying
the normal noise?
Out of product
Check for debris in the strainer
Check for a vacuum leak in the suction tube
Check suction tube & outlet hose for kinks or clogs
Check for debris in the valve plate
Check for proper voltage (+/−10%) with the pump
operating
Check upper housing for cracks
Pump will not prime
Be sure that the shut−off valve or spray tip is open &
free of debris.
If a recirculator is installed it will need to be turned
up to175psi for the pressure switch to operate
Check that the outlet hose is closed & does not leak
Check for trapped air in the head or outlet hose
Check for proper voltage (+/−10%) to pump
Check valve assembly for wear
Check for loose drive assembly or upper housing
screws
Pump will not shut off
Check pressure switch to be sure it has not been
moved out of adjustment