CUSTOMER SERVICE CENTRE   1300 780 250 

Check for loose upper housing or drive screws 

Noisy or rough operation 

Is the surface that the pump is sitting on magnifying  

the normal noise? 

Out of product 

Check for debris in the strainer 

Check for a vacuum leak in the suction tube 

Check suction tube & outlet hose for kinks or clogs 

Check for debris in the valve plate 

Check for proper voltage (+/−10%) with the pump  

operating 

Check upper housing for cracks 

Pump will not prime 

Be sure that the shut−off valve or spray tip is open & 

free of debris. 

If a recirculator is installed it will need to be turned 

up to175psi for the pressure switch to operate 

Check that the outlet hose is closed & does not leak 

Check for trapped air in the head or outlet hose 

Check for proper voltage (+/−10%) to pump 

Check valve assembly for wear 

Check for loose drive assembly or upper housing  

screws 

Pump will not shut off 

Check pressure switch to be sure it has not been  

moved out of adjustment 