It is recommended that once inspected or repaired, 
the device is marked with the date of the next 
inspection. 

Inspections are instigated by the user. If detailed 
information is required on inspection and test 
criteria, please contact your supplier or REID Lifting. 
The equipment Inspection Record can be found 
on page 31. 

If using the product in explosive atmospheres, see 
additional section titled ATEX.

Maintenance & Repair

In order to ensure correct operation, the conditions 
for inspection and maintenance must be complied 
with. If any defects are found, stop using the 
product immediately. 

No alterations or additions to the equipment 
beyond the replacement of standard parts by 
an authorised representative should be made 
without the written consent of the manufacturer. 
Any necessary repairs identified during inspections 
should only be carried out by an approved 
specialist workshop using original spare parts. Any 
repair must be carried out in accordance with the 
manufacturer’s instructions.

It is recommended to maintain the equipment in a 
clean and dry manner. Cleaning is suggested using 
a sponge or cloth with warm, soapy water, rinsing 
and allowing to dry. 

This product must be assembled using metric 
fixings of the same type and quality as those 
supplied by the original manufacturer only. Failure 
to do so could have an impact on the structural 
performance and stability of the product. REID 
Lifting and its resellers can supply these spare parts.

Storage & Transportation

When transporting the components, take note of 
all the manual handling considerations. 

Do not throw the product down or stack any 
items on top of it. 

Always place carefully and securely on the 
ground to avoid damaging the equipment.

The following information is based on REID 
Lifting’s recommendations and does not remove 
the responsibility of the user to comply with the 
relevant regulations and standards that are valid 
in the respective countries and regions where the 
system is being used.

Inspection & Maintenance

Before use, the product should be inspected for 
visual defects using the checklist below:

   

 Ensure all welds on the hub are free of cracks 
or defects

   

 Ensure levelling feet are not showing any signs 
of deformation, corrosion or damage. 

   

 Ensure all adjustment pins are not distorted or 
damaged. All pins shall be fully engaged before 
using the product. 

   

 Ensure all bolts are correctly tightened and free 
from excessive corrosion 

   

 Ensure all leg sections are free from indentation 

   

 Ensure the weight basket is retaining all weights*

   

 Ensure the weight basket is fully engaged to the 
tail before any lift*

   

 Ensure the king pin for the davit is fully engaged 
in the hub before applying a load. 

   

 Check the Davit in accordance with its 
corresponding Assembly & Operation Guide.

*Only applicable to the counterbalance system

Inspections are instigated by the user, the above list 
covers the main components on this product, any 
accessories and third-party components must be 
inspected following the corresponding instructions.

Regular Inspections

To ensure that the product’s frame remains in safe 
working order it must be inspected regularly by a 
competent or qualified person. We recommend 
inspections every 6 months for personnel lifting 
and every 12 months for goods only, unless 
local regulations, adverse working conditions or 
profile of use and risk dictate shorter periods. 
The components of the system frame need to be 
checked for damage, wear, corrosion or other 
irregularities. It may be necessary to disassemble the 
system frame in order to do this. Particular attention 
should be paid to checking the profiles for denting, 
making sure there is no wear or elongation on the 
bolt holes.

Содержание PORTA-BASE

Страница 1: ...US REIDLIFTING COM PORTABASE Assembly Operation Guide...

Страница 2: ...instructions and guidance notes carefully before using or operating the system They contain important information about how to handle and use the system in a safe and efficient way avoiding danger red...

Страница 3: ...ment to be used for lifting of materials and as a component of a PFAS Some employers may also prefer to keep such equipment distinctly separate If this is the case we would recommend that the equipmen...

Страница 4: ...any adverse weather conditions such as strong or gusty winds which could impose additional horizontal loads and affect the stability of the structure Stop using if weather is impacting on lifting and...

Страница 5: ...removed from service The substrate of the structure on which the product is placed must be able to sustain the loads specified for the device in all orientations permitted including a safety factor o...

Страница 6: ...ndicative F Maximum Rated Force Set up is indicative PFAS INFORMATION T DAVIT Type W Davit Radius Anchor Point A Anchor Point B Anchor Point C Anchor Point D Porta Base Fixed Socket 31 800 mm 22 2 kN...

Страница 7: ...NFORMATION PORTA DAVIT QUANTUM Reduced Radius PDQRW Davit Radius Anchor Point A Anchor Point B Anchor Point C Anchor Point D 31 800 mm 16 kN 3600lb 16 kN 3600lb 16 kN 3600lb 22 2 kN 5000lb This produc...

Страница 8: ...ORTA DAVIT QUANTUM 2 Winched PDQ2W Pin Position Davit Radius Anchor Point A Anchor Point B Anchor Point C Anchor Point D P1 51 1300 mm 12 kN 2600lb 12 kN 2600lb 12 kN 2600lb 22 2 kN 5000lb P2 55 1400...

Страница 9: ...formation is based on REID Lifting s recommendations and does not remove the responsibility of the user to comply with the relevant regulations and standards that are valid in the respective countries...

Страница 10: ...rown down and always placed carefully onto the ground Static Electricity For Zone 2 applications there is a potential risk of static electricity build up leading to an incentive spark To mitigate the...

Страница 11: ...sed in conjunction with the PORTA BASE 21 PORTABASE Assembling the PORTA BASE H Base Choose a suitable adjustment hole for the intended Davit Ensure all Leveling Feet are in contact with the surface s...

Страница 12: ...the Central Hub 23 PORTABASE Assembling the PORTA BASE Counterbalance Basket Assembly Choose a suitable adjustment hole for the intended Davit Ensure both Leg Assemblies are secured using the same ad...

Страница 13: ...the first side plate from the storage position at the bottom of the basket Insert the first side plate between the end plate channels Ensure the side plate sits correctly over the pin Secure in place...

Страница 14: ...asket always have the height adjustment legs fully retracted as shown in figure 2 Position the system in place for the lift before setting the height Manually raise each leg in turn and set the height...

Страница 15: ...29 PORTABASE PORTABASE Counterbalance 107 Max 91 Min 95 37 76 9 5 12 25 23 3 Height Adjustment Dimensions 13 17 45 63 72 Max 56 Min 4 Height Adjustment PORTABASE H Base...

Страница 16: ...subpart M The Lifting Operations and Lifting Equipment Regulations 1998 S I 1998 No 2307 The Provision and Use of Work Equipment Regulations 1998 S I 1998 No 2306 Machinery Directive 2006 42 EC PPE Re...

Страница 17: ...detent pin and fully engage before loading the system Insert the clevis pin and secure with the clip before loading the system Restraint point only Read the operational manuals before using the system...

Страница 18: ...The ATEX rating of the product if applicable CE Marking Minimum breaking strength MBS for ANSI Z359 18 Insert data from serial numbers found on product into table here Product labelling The following...

Страница 19: ...Date Inspected by Pass Fail Corrective Action Comments Periodic Examination Repair History 37 PORTADAVIT QUANTUM Notes Notes...

Страница 20: ...Notes Notes...

Страница 21: ...Ltd All company and product names are Trade Mark and Trade Name protected and all REID Lifting Ltd Product IPR is protected under Patents Patents Pending and or Design Rights Contact Us REID Lifting I...

Отзывы: