Specifications

  (continued)

Storage Conditions

Always place the Dust Cover on the Phoroptor when not in use to ensure that dust and other contami-

nants  do not get inside the unit.  Over time, the presence of dust and other contaminants inside the unit 

may affect operation of the Phoroptor.

Disposal

For proper disposal or recycling purposes, Reichert will take back the Phoroptor.  Please contact Reich-

ert.  The Phoroptor must not be disposed of with residential waste. 

Содержание PHOROPTOR

Страница 1: ...REICHERT PHOROPTOR Refracting Instrument User s Guide...

Страница 2: ...anges in the product described in this manual without notice and without incorporat ing those changes in any products already sold ISO 9001 13485 Certified Reichert products are designed and manufactu...

Страница 3: ...Preparation for Refraction 16 Optical Corneal Aligning Device 17 Taking Measurements 20 Distance Tests 20 Near Tests 21 Operation of the Sphere Lens Dials 22 Cylinder Power and Axis 24 Auxiliary Lens...

Страница 4: ...IS EQUIPMENT MUST ONLY BE CONNECTED TO A SUPPLY MAINS WITH PROTECTIVE EARTH OR DAMAGE TO THE INSTRUMENT AND OR INJURY TO THE OPERATOR OR PATIENT MAY OCCUR WARNING ENSURE THAT THE VOLTAGE APPLIED TO TH...

Страница 5: ...IT MAY OCCUR CAUTION DO NOT AUTOCLAVE OR DISINFECT THE UNIT OR ACCESSORIES USING HIGH TEMPERA TURES EXCEEDING THE RECOMMENDED TEMPERATURES INDICATED IN THE SPECIFICATIONS SECTION OF THIS MANUAL OR DAM...

Страница 6: ...ropean safety requirements Date of Manufacture Waste of Electrical and Electronic Equipment REF Catalog Number SN Serial Number Accompanying Documents must be consulted Fragile Contents in Shipping Co...

Страница 7: ...ronment Please retain this guide for future reference and to share with other users For additional copies of this manual or questions related to the Phoroptor contact your local authorized Reichert de...

Страница 8: ...rom the Phoroptor Refer to Figure IS 4 8 Place the packaging in a safe place so that if transportation is required in the future it will be available Your new Phoroptor refracting instrument and acces...

Страница 9: ...Lever 8 Auxiliary Lens Scale 9 Auxiliary Lens Knob 10 Corneal Aligning Device 11 Rotary Prism Unit 12 Cylinder Axis Knob 13 Cylinder Power Knob 14 Cross Cylinder Unit 15 Cylinder Power Scale 16 Cylin...

Страница 10: ...ev L Instrument Setup continued Parts Identification continued 1 Forehead Rest 2 Spring Clip 2 1 Phoroptor Back Note The configuration of the Reichert Phoroptor is a registered trademark in the United...

Страница 11: ...als Lighting is provided by energy efficient cool running LEDs light emitting diodes that require no maintenance Operators simply plug the Illuminated Phoroptor into the appropriate power receptacle t...

Страница 12: ...that comes with the stand on the Phoroptor Arm Note The instrument cannot slide off the arm at this point but can be tilted forward or back 3 Tighten the Tilt Clamp Knob and the Phoroptor will be hel...

Страница 13: ...e Shields Mounting Rotochart 1 To attach the Rotochart insert one pin into the hole slide the edge under the clip and insert the other pin into the second hole Refer to Figure SU 3 Note The Card Holde...

Страница 14: ...imeters and diopters Leveling Phoroptor 1 Move the Phoroptor into a working position 2 Use the Leveling Adjustment Knob to adjust the horizontal position of the Phoroptor Turn the Leveling Knob until...

Страница 15: ...n or occlude the apertures Note The right side of the Phoroptor the patient s left eye has white Maddox lenses and the green lens for the red green test The left side of the Phoroptor the patient s ri...

Страница 16: ...line of the test chart should be level with or slightly below the lens apertures 6 With the above accomplished lock arm motion 7 Adjust Phoroptor Forehead Rest so that the patient s corneas are approx...

Страница 17: ...be placed at a distance of 13 75 mm if the Phoroptor reading is to be directly applied to spectacle lens power 8 In the Phoroptor this condition is obtained when the zero setting of the sight in the...

Страница 18: ...between 11 00 and 12 00 the correction factor according to the table is 0 62 Therefore the power of the correction lens is obtained by adding 0 62 to 11 50 which equals 10 88 diopters when the specta...

Страница 19: ...48 57 11 00 12 25 37 51 64 78 11 00 12 24 36 46 57 68 12 00 15 30 45 61 77 93 12 00 14 28 42 55 67 80 13 00 18 35 53 72 91 1 10 13 00 16 33 48 64 78 94 14 00 21 41 62 84 1 06 1 29 14 00 19 38 55 74 9...

Страница 20: ...copy subjective phorometry are generally made with the Vergence Levers in the extreme outward position Refer to Figure TM 1 2 At this setting the lens systems are parallel For shorter test distances t...

Страница 21: ...xtreme outward position to the extreme inward position converges the instrument apertures for the near test at 16 inches At the same time aperture separation is decreased by 4mm 3 For PD settings grea...

Страница 22: ...3 Rotation of the Weak Sphere Dial upward introduces more minus power or less plus Refer to Figure TM 3 Note Plus powers are indicated by black numbers minus powers by red numbers 4 An automatic pick...

Страница 23: ...scale A quicker way rotate the Strong Sphere Control nasally one index position to introduce a value of 3 00 Rotate Weak Sphere Dial one index upward to reduce power to 2 75D To obtain a power of 7 00...

Страница 24: ...M 5 4 A pair of 0 12D cylinders in accessory cells permits refinement to 1 8th D steps 5 A pair of 2 00D cylinders in accessory cells extends cylinder power range to 8 00D 6 Large 360 protractors arou...

Страница 25: ...nce tests WMH or RMH Maddox Rod Horizontal White left eye red right eye For muscle balance tests RL Red Lens For binocular vision tests GL Green Lens For binocular vision tests O Open Aperture Second...

Страница 26: ...in or base out prism Refer to Figure IU 6 5 The Finger Roll Knob rotates the prism lenses inside the Rotary Prism Unit and varies the magnitude of prism Refer to Figure IU 7 When the Finger Roll Knob...

Страница 27: ...ubstituted 2 The power of the cross cylinder is engraved on the cell 3 Red dots indicate the minus axis and white dots the plus axis 4 A thumb operated Roll Knob provides for rapid flipping of cross c...

Страница 28: ...the axis check Procedure 1 With the tentative sphere and correcting cylinder determined by retinoscopy and or the astig matic chart in place the Cross Cylinder Unit is positioned before the aperture o...

Страница 29: ...k for axis following any modi fication made in the correcting cylinder axis and by following procedure as in a until final end point is reached c End point is reached i e correcting cylin der axis is...

Страница 30: ...s perpendicular to correcting minus cylinder axis power of correcting cylinder is reduced c End point is obtained i e correcting cylin der power is correct when vision is equally impaired by flipping...

Страница 31: ...TACTED WILL BE SOILED Sanitary Face Shields The semi permanent Face Shields furnished with the Phoroptor are made of white nylon and have a protective lens on them to help keep the inside of the Phoro...

Страница 32: ...cleaning solution is desirable 4 Indirect illumination from a standard lamp bulb through the instrument apertures will help identify soiled lenses Lenses may be cleaned with the Phoroptor in place on...

Страница 33: ...retaining washers 10 To lock new cell into position turn the screw 1 4 turn rotate washer so that flat side is 900 away from cell tighten the screw firmly 11 Repeat for the other screw and washer Repl...

Страница 34: ...and MM 2 1 Using a 0 060 6 Spline Screwdriver remove the two spline screws 2 Lift off the retaining ring 3 Lift out the complete Cross Cylinder Lens Assembly 4 Reverse the procedure to install a new...

Страница 35: ...pressure of the wheel in the dial index deter mines to a considerable degree the feel of the dial rotation and indexing Each may be adjusted from the outside of the in strument with no dismantling re...

Страница 36: ...ct input voltage Light may be turned all the way down Turn the Rheostat Control knob all the way up Weak Sphere Dial Too Loose or Tight Tighten or loosen the coordinating screw on the bottom of the ph...

Страница 37: ...Reading Distance 5 to 28 Centimeter and diopter scales included Auxiliary Dial 10 lenses plus 2 open apertures Electrical Illuminated Phoroptor Only Power Adaptor 11636 401 Power Adaptor 11636 405 In...

Страница 38: ...dust and other contami nants do not get inside the unit Over time the presence of dust and other contaminants inside the unit may affect operation of the Phoroptor Disposal For proper disposal or recy...

Страница 39: ...phthalmic Instrument Dealer Furthermore Reichert shall not be liable for costs of procurement of substitute goods by anyone How to File a Claim Any claim under this warranty must be made within 30 day...

Страница 40: ...716 686 4555 Email reichert information ametek com www reichert com AMETEK GmbH Business Unit Reichert Carl von Linde Strasse 42 85716 Unterschleissheim Munich Germany Email info reichert de ametek c...

Отзывы: