29
Repeating the Deletion Processes
If the deletion process was unsuccessful, the central
vacuum unit‘s LCD display will read “CLR“ for 1
second, followed by “FAIL“ for 3 seconds.
These two messages can repeat themselves up to 10
times.
1. Wait until the operating hours are displayed on the
central vacuum unit‘s LCD display.
2. Briefly press either the ON or OFF button.
3. Try to delete the transmitter again.
Make sure the handle/manual transmitter remains
against the central vacuum unit‘s housing and that
the OFF button is pressed and held down for 5
seconds.
1. Hold the suction hose handle or the manual trans-
mitter against the central vacuum unit (refer to Fig.
4).
2. Press and hold down the OFF button for 5 seconds
without
moving the transmitter away from the
central vacuum unit.
If the deletion process was successful, the following
appear on the central vacuum unit‘s LCD display:
- “LERN“ (“TEACH“ in English) for 2 seconds;
- “CLR“ for 3 seconds;
- “OK“ for 2 seconds;
- Alternating “FFB“ and “OPEN“.
3. Reteach the transmitter if desired.
Deleting Stored Transmitter Information
Deleting the information on a single transmitter will
cause the information on
all
taught transmitters and
repeaters to be deleted.
Connecting the Control Cable
1. Remove the contact plug of the control cable outlet
from the central vacuum unit (refer to Fig. 5).
2. Connect the control cable wires to the contact plug
(refer to Fig. 6).
3. Plug the contact connector with the attached control
cable wires back into the central control cable outlet.
Fig. 5 Contact plug outlet removal
Fig. 6 Connecting the control cable wires to the contact plug