MAinTenAnce nOTes
regular inspection:
repairs:
Danger of injury!
Always remove the battery before cleaning and inspection .
- Always keep jaw sets, expanding tools and cylinders clean .
When soiled, clean them with a brush and oil them . Then store the
tool in a dry place
- Before every use, check the jaw sets, expanding tools and the
G2 basic tool for damage or visible wear . Damaged tools may no
longer be used and should immediately be sent to an authorised
service center for repair
- Make sure that the jaw sets are fully applied across the whole
surface and at a right angle during the compression process and
the compression sleeve is inserted up to the fitting collar
- regularly grease the expanding tool tapers . Do not apply grease
to the surface of expander segments . Should excess grease reach
the expander segments, the segments must be thoroughly cleaned
(e .g . cleaning solvent) and then dried
- Before starting the coupling process, check quick-coupler for
impurities/dirt and clean with cloth if required
- fit dust corers conto quick-coupler once the uncoupling procedure
is completed
risk of accident!
Do not perform any repairs on the tool yourself . repairs should only be
carried out by an authorised service center .
Storage:
never store the tool if wet! Dry the tool and grease it . Then store it in
a dry place .