Regulus TRS 5 Скачать руководство пользователя страница 26

 

26

REGULUS - TRS 5 Controller - www.regulus.eu

G - DEFECTS AND MAINTENANCE

G 1 - Malfunctions with error messages

If the controller detects a malfunction, the red light 

fl

ashes and the warning symbol also appears in the 

display. If the error is no longer present, the warning 
symbol changes to an info symbol and the red light no 
longer 

fl

ashes.

To obtain more detailed information on the error, 
press the key under the warning or info symbol. 
Do not try to deal with this yourself. 
Consult a specialist in the event of an error!

Possible error messages: 

 

Notes for the specialist:

Sensor x defective 

 

 

Means that either the sensor, the sensor input at the controller or the  

 

 

 

 

 

connecting cable is/was defective. (Resistance table see chap. A6)

Restart 

    Means that the controller was restarted, for example due to a power failure.  

(Information only) 

 

 

Check the date&time!

(Led  warning symbol) 

Содержание TRS 5

Страница 1: ...TRS 5 Controller EN v 1 1 Installation wiring and operating instructions...

Страница 2: ...devices to be provided by the customer e g a safety valve air vent valve etc The installation shall be done by a qualified specialist who is trained accordingly For the user Make sure that the specia...

Страница 3: ...s E Controller Use E 1 Display and input 10 E 2 Menu sequence and menu structure 11 E 3 Commissioning help setup wizard 12 E 4 Free commissioning 12 F Parameter Setting F 1 Measurements 13 F 2 Statist...

Страница 4: ...ontroller operation max 85 rel humidity at 25 C for transport storage no moisture condensation permitted Other specifications and dimensions Housing design 2 part ABS plastic Installation method wall...

Страница 5: ...by means of statistical graphics extensive menus with interactive explanations menu lock can be activated to prevent unintentional setting changes usual preset parameters in factory setting A 3 Scope...

Страница 6: ...nts may be mandatory such as check valves non return valves safety temperature limiters scalding protectors etc and must therefore be provided 1 Mixed heating circuit with accumulation tank 2 Mixed he...

Страница 7: ...hen doing so 4 Hold the lower part of the housing up to the selected position and mark the 3 mounting holes Make sure that the wall surface is as even as possible so that the housing does not become d...

Страница 8: ...g with a screwdriver Fig C 2 1 and wire the cables following the diagrams in section D 5 Lock the housing lid onto the top margin of its bottom counterpart push the cables inside and close the housing...

Страница 9: ...tional expansion Z2 optional expansion Use terminal block S for connecting the sensor earths of S1 S6 The polarity is freely selectable The sensors S3 S6 are optional depending on the hydraulic varian...

Страница 10: ...ey 3 is used to cancel an entry or to exit a menu If applicable there will be a request for confirmation as to whether the changes which have been made should be saved The function of each of the othe...

Страница 11: ...ol of the system with operating hours etc 3 Operating times for heating circuit and DHW setting the clock 4 Operating times for heating circuit and DHW manual mode 5 Set parameters for the heating cir...

Страница 12: ...step to the selection mode thus cancelling the commissioning help Finally menu 4 2 under operating mode Manual should be used to test the switch outputs with the consumers connected and to check the...

Страница 13: ...Overview or esc exits the Info mode If Error appears on the display instead of the measurement value then there may be a defective temperature sensor or its wiring If the cables are too long or the se...

Страница 14: ...the unit of time and the two left buttons scroll through the diagram F 2 2 28 days Menu 2 2 flow temperature during the last 28 days In the graphical overview the characteristics of the outdoor and fl...

Страница 15: ...which the heating circuit is supplied with an increased comfort temperature e g for quick heating in the morning Setting range One time range for each day of the week Default Mo Su off Note See 5 for...

Страница 16: ...ual mode the individual relay outputs and the connected consumers can be checked for proper functioning and correct assignment The operating mode Manual may only be used by specialists for brief funct...

Страница 17: ...l straight curve Setting simple or a split curve Setting split that is divided into 2 parts by a split point The straight curve can be set easily using one parameter The characteristic curve for the s...

Страница 18: ...erature in nighttime operation that is by 7 C below that of daytime operation Setting range from 30 C to 30 C Default 2 C F 5 6 Comfort temperature boost menu 5 6 paraleln posun k ivky The comfort tem...

Страница 19: ...C F 6 2 DHW Setpoint menu 6 2 Minimum domestic hot water temperature If the temperature at the DHW sensor S3 drops below the temperature set here and the DHW charging is enabled the DHW charging rela...

Страница 20: ...ure of the heating circuit Should the heating circuit temperature exceed this value the heating circuit is switched off until the temperature drops below This feature is used e g to protect underfloor...

Страница 21: ...d Pressing the esc more than once takes you back step by step to the selection mode thus cancelling the commissioning help see also E3 May only be started by a specialist during commissioning Observe...

Страница 22: ...in the room temperature has on the reference flow temperature For every degree of deviation of the room temperature from the reference room temperature the percentage of the calculated reference flow...

Страница 23: ...closed by pressing esc or selecting Exit menu lock The menus listed below remain completely accessible despite the menu lock being activated and can be used to make adjustments if necessary F 1 Measur...

Страница 24: ...e following table The menu can be closed at any time by pressing esc Caution 10 1 10 31 10 2 10 32 10 3 10 33 10 4 10 34 10 5 10 35 10 6 10 36 10 7 10 37 10 8 10 38 10 9 10 39 10 10 10 40 10 11 10 41...

Страница 25: ...egulus eu Language menu 11 F 11 Language Menu 11 Language can be used to select the language for the menu guidance This is queried automatically during initial commissioning Language selection is not...

Страница 26: ...hes To obtain more detailed information on the error press the key under the warning or info symbol Do not try to deal with this yourself Consult a specialist in the event of an error Possible error m...

Страница 27: ...d fuse and check it Exchange the defective fuse for a new one locate the external source of the error e g pump and exchange it Then first recommission the controller and check the function of the swit...

Страница 28: ...rd any analyses and data that are particularly important to you at regular intervals see 7 IMPORTANT INFORMATION ON DISPOSAL IN COMPLIANCE WITH THE EUROPEAN DIRECTIVE 2002 96 EC European Directive 200...

Отзывы: