15
│
REGULUS - TRS 5 Controller - www.regulus.eu
Times
menu 3
F 3 - Times
Menu
„3. Times”
is used to set the time, date and
operating times for the heating circuit and DHW.
The associated temperature reference
values are speci
fi
ed in menu 5
„Settings”
!
The menu is closed by pressing
„esc”
or selecting
„Exit times”
.
F 3.1 - Time & Date
menu 3.1
This menu is used to set the current time and date.
For proper functioning of the controller and statistics for the system data it is essential for the time
to be set accurately on the controller. Please note that the clock continues to run for about 24
hours if the mains voltage is interrupted, and after that has to be reset.
F 3.2 - Heating circuit day
menu 3.2
This menu is used to select the daytime mode times for the heating circuit; three time periods can be speci
fi
ed
for each weekday and copied over to the following days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su 6:00-22:00
Note: See 5. for the associated temperature settings
Times that are not speci
fi
ed are automatically considered to be nighttime mode. The set times are
only taken into account in the heating circuit operating mode
„Automatic”
.
F 3.3 - Heating comfort
menu 3.3
This menu can be used to select a time range for each day of the week in which the heating circuit is supplied
with an increased comfort temperature, e.g. for quick heating in the morning.
Setting range: One time range for each day of the week
Default: Mo-Su off.
Note: See 5. for the associated temperature settings
F 3.4 - Hot water enable
menu 3.4
This menu is used to select the times when the domestic hot water heating is enabled (sensor 3); three time
periods can be speci
fi
ed for each weekday and copied over to the following days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su 6:00-22:00
Note: See 6. for the associated temperature settings
Times that are not speci
fi
ed are set to
„disabled”
.
F 3.5 - Hot water AL
menu 3.5
A period of time can be set here for each week day when the domestic hot water part of the installation
(sensor 3) is heated up to higher temperature, e.g. for anti Legionella function.
Setting range: One period of time for each day of the week
Default: Mo-Su off
Note: See 7.5. for the associated temperature settings
This anti-Legionella function does not provide complete protection against Legionella, because
the controller is dependent on suf
fi
cient energy being fed in, and it is not possible to monitor the
temperatures in the entire range of the storage tanks and the connected piping system. To provide
complete protection against Legionella bacteria, it must be ensured that the temperature is raised
to the necessary value (see section 5 for more info).
Caution
Caution
Caution
Caution
Caution