12
REGULUS - TRS 4 Controller - www.regulus.eu
E 3 - Commissioning help - setup wizard
The first time the controller is turned on, language and
clock need to be set.
After that a query appears as to whether you want to
parameterize the controller using the commissioning
help or not. The commissioning help can also be
terminated or called up again at any time in the
special functions menu. The commissioning help
guides you through the necessary basic settings in
the correct order, and provides brief descriptions of
each parameter in the display. Pressing the
„esc”
key
takes you back to the previous value so you can look
at the selected setting again or adjust it if desired.
Pressing the
„esc”
more than once takes you back
step by step to the selection mode, thus cancelling
the commissioning help. Finally, menu 4.3 under
operating mode
„Manual”
should be used to test the switch outputs with the consumers connected, and to
check the sensor values for plausibility. Then switch on automatic mode.
E 4 - Free commissioning
If you decide not to use the commissioning help, you should make the necessary settings in the following
sequence:
- Menu 10.
Language
- Menu 3.
Time, date and operating times
- Menu 5.
Settings for the heating circuit
- Menu 7.
Protective functions if necessary
- Menu 8.
Special functions if necessary
Finally, menu 4.3 under operating mode
„Manual”
should be used to test the switch outputs with the
consumers connected, and to check the sensor values for plausibility. Then switch on automatic mode.
Observe the explanations for the individual parameters on the following pages, and check whether
further settings are necessary for your application.
Settings for heating circuit 2 are not included in the Setup wizard. These settings shall be adjusted
in Menu 6
„HC2 Settings”
.
Caution
Caution