12
RTC 13e - www.regulus.eu
a) Installation on concrete blocks
The heat pump is placed on the legs at the factory. The heat pump supplied in this way shall
be installed on concrete blocks.
- The foundations of concrete blocks should
reach a frost-free depth.
-
At the end, level the equipment with a spirit
level.
b) Installation on wall brackets
The other option is to place the heat pump on the house structure using wall brackets (code
17458). In such a case, it is necessary to remove the silent blocks with M10 thread and
replace them with silent blocks supplied with the brackets (40 mm high). The brackets are
galvanized and the complete support is supplied including steel ropes ensuring its spatial
rigidity.
- Before mounting the bracket on the
wall, it is important to verify its load-
bearing capacity and select a suitable
method of mounting – e.g. using a
chemical anchor or a through-wall
anchor.
- Follow the instructions for the wall
mounting brackets.
- At the end, level the equipment with
a spirit level.
Wall brackets (code 17458)
coarse
crushed stone,
32-63 mm
concrete blocks
min.width 100 mm
in frost-free depth
Содержание RTC 13e
Страница 7: ...7 RTC 13e www regulus eu 2 4 Heat pump pressure drop 2 5 Dimensions 413 936 ...
Страница 26: ... 26 RTC 13e www regulus eu ...
Страница 27: ...27 RTC 13e www regulus eu ...