3 - Configuration menu
The Bulleur has a button inside the cabinet to adjust various parameters of the installation
The « configuration » menu allows you to select the original functions
When the Bulleur is switched on,
on the display a segment loops for 3 sec, press the key to enter
the setup/configuration menu
Chlore
pH
Sel
Temp
Configuration Consigne Calibration
N2
N3
N1
S
STOP
clic 2"
Configuration
clic
Configuration
Configuration
clic
clic 2"
clic
Tempo rain
Configuration
Configuration
factory setting 1h
clic
clic 2"
Factory setting
Configuration
Configuration
-
+
« NON ou OUI »
clic
clic 2"
Function Emptying
Configuration
Configuration
factory setting OFF
-
+
OFF ON
clic
clic 2"
a long click on the button
to modify a data
a single click
to validate
then appears on the screen
Security filling
to exit the menu
switch off the device
factory setting 1h
Security filling
N2
STOP
Configuration
from off to 3hours(30 min steps)
security
after reaching N3
stopping the filtering
force at the end of
the set tempo filtration
is restarted for 15 min
every 60 min
flashes
Return
Warning
« OFF » makes it possible not to take it into account a function
For exemple:
OFF filling (more filing safety)
OFF tempo rain (filtration is forced whenever the level
is above N2)
OFF drain (removes the control function of a drain pump)
11
Régul’ Electronique
flashes
flashes
flashes
from off to 3h(30 min steps)
security
too much filling
« DEF REMPLIS »
is displayed after the set
continuous filling time
If « ON » the drain
pump is controlled at
the set threshold
until it falls below
the threshold N2
Back to
all factory settings,
configurations
and levels