V
09/2011
Temperature Control Unit 300L(D)/350L(D)
Maintenance
•
25
Technical Data 350L(D)
Temperature Control Unit
Type
350L
350LD
Max. outlet temperature
350 °C
350 °C
Heat transfer medium
Oil
Oil
Filling capacity
15 litres
24 litres
Max. expansion volume
20 litres
20 litres
Heating capacity at 400 V
20 kW
20 kW (per circuit)
Heating switch
SSR relay
SSR relay
Cooling capacity
80 kW
80 kW (per circuit)
at outlet temperature
280 °C
280 °C
Pump type
FM65
FM65
Power consumption
2.8 kW
2.8 kW (per circuit)
Max. delivery rate
90 l/min
90 l/min (per circuit)
Max. delivery pressure
10 bar
10 bar (per circuit)
Control System
RT100 Control System
Measurement type (standard)
Pt100 Pt100
Control voltage
230 V, 50 Hz
230 V, 50 Hz
Input supply voltages
200-600 V
50/60 Hz
200-600 V
50/60 Hz
Input supply voltage
(standard)
400 V/50 Hz, 3 PE
400 V/50 Hz, 3 PE
Outlet/inlet connections (stan-
dard)
G 3/4" female
G 3/4" female
Cooling water supply connec-
tions (standard)
G 3/4"
G 3/4"
Degree of protection
IP54
IP54
Dimensions W/H/D
432/1579/1466 mm
546/1579/1466 mm
Weight
approx. 323 kg
approx. 642 kg
Colour
RAL 9006/7016
RAL 9006/7016
Ambient temperature
max. 40 °C
max. 40 °C
Continuous sound pressure
level
< 70 dB(A)
< 70 dB(A)
Содержание 300L